Datasheet
ADG601/ADG602
Rev. C | Page 5 of 12
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 4.
Parameter Rating
V
DD
to V
SS
13 V
V
DD
to GND −0.3 V to +6.5 V
V
SS
to GND +0.3 V to –6.5 V
Analog Inputs
1
V
SS
− 0.3 V to V
DD
+ 0.3 V
Digital Inputs
1
−0.3 V to V
DD
+ 0.3 V or
30 mA (whichever
occurs first)
Continuous Current, S or D 100 mA
Peak Current, S or D
(Pulsed at 1 ms, 10% Duty Cycle Max) 200 mA
Operating Temperature Range
Industrial (B Version) −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Junction Temperature 150°C
Thermal Resistance
MSOP
θ
JA
206°C/W
θ
JC
44°C/W
SOT-23
θ
JA
229.6°C/W
θ
JC
91.99°C/W
Lead Temperature, Soldering (10 sec) 300°C
IR Reflow, Peak Temperature 220°C
1
Overvoltages at IN, S, or D are clamped by internal diodes. Current should be
limited to the maximum ratings given.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Only one absolute maximum rating may be applied at a time.
ESD CAUTION