Datasheet
ADG5212/ADG5213
Rev. 0 | Page 7 of 20
Parameter 25°C −40°C to +85°C −40°C to +125°C Unit Test Conditions/Comments
−3 dB Bandwidth 410 MHz typ R
L
= 50 Ω, C
L
= 5 pF,
see Figure 28
Insertion Loss −6.8 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz,
see Figure 28
C
S
(Off) 3 pF typ V
S
= 18 V, f = 1 MHz
C
D
(Off) 5 pF typ V
S
= 18 V, f = 1 MHz
C
D
(On), C
S
(On) 8 pF typ V
S
= 18 V, f = 1 MHz
POWER REQUIREMENTS V
DD
= 39.6 V
I
DD
80 μA typ Digital inputs = 0 V or V
DD
100 130 μA max
V
DD
9/40 V min/V max GND = 0 V, V
SS
= 0 V
1
Guaranteed by design; not subject to production test.
CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx
Table 5.
Parameter 25°C 85°C 125°C Unit
CONTINUOUS CURRENT, Sx or Dx
V
DD
= +15 V, V
SS
= −15 V
TSSOP (θ
JA
= 112.6°C/W) 18 10 5 mA maximum
LFCSP (θ
JA
= 30.4°C/W) 32 15 6 mA maximum
V
DD
= +20 V, V
SS
= −20 V
TSSOP (θ
JA
= 112.6°C/W) 29 16 8 mA maximum
LFCSP (θ
JA
= 30.4°C/W) 50 22 9 mA maximum
V
DD
= 12 V, V
SS
= 0 V
TSSOP (θ
JA
= 112.6°C/W) 18 12 7 mA maximum
LFCSP (θ
JA
= 30.4°C/W) 32 17 8 mA maximum
V
DD
= 36 V, V
SS
= 0 V
TSSOP (θ
JA
= 112.6°C/W) 34 18 8 mA maximum
LFCSP (θ
JA
= 30.4°C/W) 59 24 9 mA maximum