Parameter Symbol Test Conditions/Comments Min Typ Max Unit
1.15 V to 1.3 V ≤ V
CCA
≤ V
CCY
, V
CCY
= 1.8 V ± 0.3 V
AY Translation
R
S
= R
T
= 50 Ω, C
L
= 50 pF, see Figure 37
Propagation Delay
t
P, AY
12 25 ns
Rise Time
t
R, AY
7 12 ns
Fall Time
t
F, AY
3 5 ns
Maximum Data Rate
D
MAX, AY
25 Mbps
Channel-to-Channel Skew
t
SKEW, AY
2 5 ns
Part-to-Part Skew
t
PPSKEW, AY
15 ns
Y
A Translation
S
T
L
Propagation Delay
t
P, YA
14 35 ns
Rise Time
t
R, YA
5 16 ns
Fall Time
t
F, YA
2.5 6.5 ns
Maximum Data Rate
D
MAX, YA
25 Mbps
Channel-to-Channel Skew
t
SKEW, YA
3 6.5 ns
Part-to-Part Skew
t
PPSKEW, YA
23.5 ns
2.5 V ± 0.2 V ≤ V
CCA
≤ V
CCY
, V
CCY
= 3.3 V ± 0.3 V
AY Translation
R
S
= R
T
= 50 Ω, C
L
= 50 pF, see Figure 37
Propagation Delay
t
P, AY
7 10 ns
Rise Time
t
R, AY
2.5 4 ns
Fall Time
t
F, AY
2 5 ns
Maximum Data Rate
D
MAX, AY
60 Mbps
Channel-to-Channel Skew
t
SKEW, AY
1.5 2 ns
Part-to-Part Skew
t
PPSKEW, AY
4 ns
Y
A Translation
R
S
= R
T
= 50 Ω, C
L
= 15 pF, see Figure 38
Propagation Delay
t
P, YA
5 8 ns
Rise Time
t
R, YA
1 4 ns
Fall Time
t
F, YA
3 5 ns
Maximum Data Rate
D
MAX, YA
60 Mbps
Channel-to-Channel Skew
t
SKEW, YA
2 3 ns
Part-to-Part Skew
t
PPSKEW, YA
3 ns
POWER REQUIREMENTS
Power Supply Voltages V
CCA
V
CCA
≤ V
CCY
1.15 5.5 V
V
CCY
1.65 5.5 V
Quiescent Power Supply Current I
CCA
V
A
= 0 V/V
CCA
, V
Y
= 0 V/V
CCY
,
V
CCA
= V
CCY
= 5.5 V, EN = 1
0.17 5 µA
I
CCY
V
A
= 0 V/V
CCA
, V
Y
= 0 V/V
CCY
,
V
CCA
= V
CCY
= 5.5 V, EN = 1
0.27 5 µA
Three-State Mode Power Supply Current I
Hi-Z, A
V
CCA
= V
CCY
= 5.5 V, EN = 0 0.1 5 µA
I
Hi-Z, Y
V
CCA
= V
CCY
= 5.5 V, EN = 0 0.1 5 µA
1
T
A
for typical specifications is 25°C.