Datasheet
Table Of Contents

Data Sheet ADG1414
Rev. A | Page 5 of 20
Parameter +25°C
−40°C to
+85°C
−40°C to
+125°C Unit Test Conditions/Comments
DYNAMIC CHARACTERISTICS
1
t
ON
145 ns typ R
L
= 100 Ω, C
L
= 35 pF
185 220 240 ns max V
S
= 8 V; see Figure 30
t
OFF
35 ns typ R
L
= 100 Ω, C
L
= 35 pF
45 46 46 ns max V
S
= 8 V; see Figure 30
Charge Injection 8 pC typ V
S
= 6 V, R
S
= 0 Ω, C
L
= 1 nF; see
Figure 31
Off Isolation −70 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz;
see Figure 26
Channel-to-Channel Crosstalk −75 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz;
see Figure 27
−3 dB Bandwidth 240 MHz typ R
L
= 50 Ω, C
L
= 5 pF; see Figure 28
Insertion Loss 1.15 dB typ R
L
= 50 Ω, C
L
= 5 pF, f = 1 MHz; see
Figure 28
C
D
, C
S
(Off ) 12 pF typ f = 1 MHz
C
D
, C
S
(On) 33 pF typ f = 1 MHz
POWER REQUIREMENTS V
DD
= +13.2 V
I
DD
0.001 µA typ Digital inputs = 0 V or V
L
1 µA max
I
L
Inactive 0.3 µA typ Digital inputs = 0 V or V
L
1 µA max
I
L
Active @ 30 MHz 0.26 mA typ Digital inputs toggle between 0 V
and V
L
0.3 0.35 mA max
I
L
Active @ 50 MHz 0.42 mA typ Digital inputs toggle between 0V
and V
L
0.5 0.55 mA max
I
SS
0.001 µA typ Digital inputs = 0 V or V
L
1 µA max
V
DD
/V
SS
±4.5/±16.5 V min/max
1
Guaranteed by design, not subject to production test.