Datasheet
ADG1406/ADG1407
Rev. A | Page 7 of 20
Parameter +25°C
−40°C to
+85°C
−40°C to
+125°C
1
Unit Test Conditions/Comments
POWER REQUIREMENTS V
DD
= +5.5 V, V
SS
= −5.5 V
I
DD
0.002 μA typ Digital inputs = 0 V or V
DD
1 μA max
I
SS
0.002 μA typ Digital inputs = 0 V, 5 V, or V
DD
1 μA max
V
DD
/V
SS
±4.5/±16.5 V min/max
1
Temperature range for B version: −40°C to +125°C.
2
Guaranteed by design, not subject to production test.
CONTINUOUS CURRENT PER CHANNEL
Table 5. ADG1406
Parameter 25°C 85°C 125°C Unit Test Conditions/Comments
CONTINUOUS CURRENT PER CHANNEL
1
15 V Dual Supply V
DD
= +13.5 V, V
SS
= −13.5 V
28-Lead TSSOP 180 100 50 mA max
32-Lead LFCSP 300 150 60 mA max
12 V Single Supply V
DD
= 10.8 V, V
SS
= 0 V
28-Lead TSSOP 150 90 50 mA max
32-Lead LFCSP 260 130 55 mA max
5 V Dual Supply V
DD
= +4.5 V, V
SS
= −4.5 V
28-Lead TSSOP 140 85 45 mA max
32-Lead LFCSP 245 130 55 mA max
1
Guaranteed by design, not subject to production test.
Table 6. ADG1407
Parameter 25°C 85°C 125°C Unit Test Conditions/Comments
CONTINUOUS CURRENT PER CHANNEL
1
15 V Dual Supply V
DD
= +13.5 V, V
SS
= −13.5 V
28-Lead TSSOP 135 85 45 mA max
32-Lead LFCSP 235 125 55 mA max
12 V Single Supply V
DD
= 10.8 V, V
SS
= 0 V
28-Lead TSSOP 110 70 40 mA max
32-Lead LFCSP 190 110 50 mA max
5 V Dual Supply V
DD
= +4.5 V, V
SS
= −4.5 V
28-Lead TSSOP 105 65 40 mA max
32-Lead LFCSP 180 100 50 mA max
1
Guaranteed by design, not subject to production test.