Datasheet
ADG1236
Rev. 0 | Page 9 of 16
TYPICAL PERFORMANCE CHARACTERISTICS
SOURCE OR DRAIN VOLTAGE (V)
ON RESISTANCE (Ω)
200
100
0
–18 –15 –12 –9 –6 –3 12 15906318
04776-011
180
160
140
120
80
60
40
20
T
A
= 25°C
V
DD
= 15V
V
SS
= –15V
V
DD
= 16.5V
V
SS
= –16.5V
V
DD
= 13.5V
V
SS
= –13.5V
Figure 4. On Resistance as a Function of V
D
(V
S
) for Dual Supply
SOURCE OR DRAIN VOLTAGE (V)
ON RESISTANCE (Ω)
600
300
0
–6 –4 –2 402 6
04776-012
500
400
200
100
T
A
= 25°C
V
DD
= 5V
V
SS
= –5V
V
DD
= 5.5V
V
SS
= –5.5V
V
DD
= 4.5V
V
SS
= –4.5V
Figure 5. On Resistance as a Function of V
D
(V
S
) for Dual Supply
SOURCE OR DRAIN VOLTAGE (V)
ON RESISTANCE (Ω)
450
250
300
0
02 46 12810 14
04776-013
400
350
150
200
100
50
T
A
= 25°C
V
DD
= 12V
V
SS
= 0V
V
DD
= 13.2V
V
SS
= 0V
V
DD
= 10.8V
V
SS
= 0V
Figure 6. On Resistance as a Function of V
D
(V
S
) for Single Supply
TEMPERATURE (°C)
ON RESISTANCE (Ω)
250
0
–15 –10 –5 1005 15
04776-014
150
200
100
50
T
A
= +25°C
T
A
= +85°C
T
A
= +125°C
T
A
= –40°C
V
DD
= 15V
V
SS
= –15V
Figure 7. On Resistance as a Function of V
D
(V
S
) for Different Temperatures,
Dual Supply
TEMPERATURE (°C)
ON RESISTANCE (Ω)
600
0
024 1068 12
04776-015
300
400
200
500
100
T
A
= +25°C
T
A
= +85°C
T
A
= +125°C
T
A
= –40°C
V
DD
= 12V
V
SS
= 0V
Figure 8. On Resistance as a Function of V
D
(V
S
) for Different Temperatures,
Single Supply
TEMPERATURE (°C)
LEAKAGE (nA)
0.20
–0.20
0 20 40 10060 80 120
04776-016
0
0.05
0.10
0.15
–0.05
–0.15
–0.10
I
D
, I
S
(ON)
I
S
(OFF)
V
DD
= 15V
V
SS
= –15V
V
BIAS
= +10V/–10V
Figure 9. Leakage Currents as a Function of Temperature, Dual Supply