Datasheet
ADG1208/ADG1209
Rev. B | Page 4 of 20
Parameter +25ºC
−40ºC to
+85ºC
−40ºC to
+125ºC Unit Test Conditions/Comments
C
D
, C
S
(On) ADG1208 7 pF typ f = 1 MHz, V
S
= 0 V
8 pF max f = 1 MHz, V
S
= 0 V
C
D
, C
S
(On) ADG1209 5 pF typ f = 1 MHz, V
S
= 0 V
6 pF max f = 1 MHz, V
S
= 0 V
POWER REQUIREMENTS V
DD
= +16.5 V, V
SS
= −16.5 V
I
DD
0.002 μA typ Digital inputs = 0 V or V
DD
1.0 μA max
I
DD
220 μA typ Digital inputs = 5 V
380 μA max
I
SS
0.002 μA typ Digital inputs = 0 V or V
DD
1.0 μA max
I
SS
0.002 μA typ Digital inputs = 5 V
1.0 μA max
V
DD
/V
SS
±5/±16.5 V min/max |V
DD
| = |V
SS
|
1
Temperature range is as follows: Y version: –40°C to +125°C.
2
Guaranteed by design, not subject to production test.