Datasheet

ADG1206/ADG1207
Rev. A | Page 4 of 20
Parameter +25°C
−40°C to
+85°C
−40°C to
+125°C Unit Test Conditions/Comments
C
D
, C
S
(On) ADG1206 13 pF typ f = 1 MHz, V
S
= 0 V
15 pF max f = 1 MHz, V
S
= 0 V
C
D
, C
S
(On) ADG1207 8 pF typ f = 1 MHz, V
S
= 0 V
10 pF max f = 1 MHz, V
S
= 0 V
POWER REQUIREMENTS V
DD
= +16.5 V, V
SS
= −16.5 V
I
DD
0.002 μA typ Digital inputs = 0 V or V
DD
1.0 μA max
I
DD
260 μA typ Digital inputs = 5 V
475 μA max
I
SS
0.002 μA typ Digital inputs = 0 V, 5 V, or V
DD
1.0 μA max
V
DD
/V
SS
±5/±16.5 V min/max GND = 0V
1
Temperature range for Y version is 40°C to +125°C.
2