Datasheet

ADF4360-4
Data Sheet
Rev. B | Page 4 of 24
Parameter B Version Unit Conditions/Comments
NOISE CHARACTERISTICS
5
VCO Phase-Noise Performance
8
111 dBc/Hz typ @ 100 kHz offset from carrier.
133 dBc/Hz typ @ 1 MHz offset from carrier.
141 dBc/Hz typ @ 3 MHz offset from carrier.
147
dBc/Hz typ
Synthesizer Phase-Noise Floor
9
172 dBc/Hz typ @ 25 kHz PFD frequency.
163 dBc/Hz typ @ 200 kHz PFD frequency.
147 dBc/Hz typ @ 8 MHz PFD frequency.
In-Band Phase Noise
10, 11
85 dBc/Hz typ @ 1 kHz offset from carrier.
RMS Integrated Phase Error
12
0.56 Degrees typ 100 Hz to 100 kHz.
Spurious Signals due to PFD Frequency
11, 13
65 dBc typ
Level of Unlocked Signal with MTLD Enabled 48 dBm
1
Operating temperature range is 40°C to +85°C.
2
Guaranteed by design. Sample tested to ensure compliance.
3
I
CP
is internally modified to maintain constant loop gain over the frequency range.
4
T
A
= 25°C; AV
DD
= DV
DD
= V
VCO
= 3.3 V; P = 32.
5
These characteristics are guaranteed for VCO core power = 15 mA.
6
Jumping from 1.45 GHz to 1.75 GHz. PFD frequency = 200 kHz; loop bandwidth = 10 kHz.
7
Using 50 resistors to V
VCO
into a 50 load. For tuned loads, see the Output Matching section.
8
The noise of the VCO is measured in open-loop conditions.
9
The synthesizer phase-noise floor is estimated by measuring the in-band phase noise at the output of the VCO and subtracting 20 log N (where N is the N divider value).
10
The phase noise is measured with the EV-ADF4360-4EB1Z Evaluation Board and the HP8562E Spectrum Analyzer. The spectrum analyzer provides the REF
IN
for the
synthesizer; offset frequency = 1 kHz.
11
f
REFIN
= 10 MHz; f
PFD
= 200 kHz; N = 8000; Loop B/W = 10 kHz.
12
f
REFIN
= 10 MHz; f
PFD
= 1 MHz; N = 1600; Loop B/W = 25 kHz.
13
The spurious signals are measured with the EV-ADF4360-4EB1Z Evaluation Board and the HP8562E Spectrum Analyzer. The spectrum analyzer provides the REF
IN
for
the synthesizer; f
REFOUT
= 10 MHz @ 0 dBm.