Datasheet

ADF4106 Data Sheet
Rev. E | Page 16 of 24
Table 10. Initialization Latch Map
P2 P1
0 0 8/9
0 1 16/17
1 0 32/33
1 1 64/65
PD2 PD1 MODE
0
X
X
1
X 0
1 0 1
1 1 1
CPI6 CPI5 CPI4
CPI3 CPI2 CPI1
3k 5.1k 11k
0 0 0 1.06 0.625 0.289
0 0 1 2.12 1.25 0.580
0 1 0 3.18 1.875 0.870
0 1 1 4.24 2.5 1.160
1 0 0 5.30 3.125 1.450
1 0 1 6.36 3.75 1.730
1 1 0 7.42 4.375 2.020
1 1 1 8.50 5.0 2.320
TC4 TC3 TC2 TC1
0 0 0 0 3
0 0 0 1 7
0 0 1 0 11
0 0 1 1 15
0 1 0 0 19
0 1 0 1 23
0 1 1 0 27
0 1 1 1 31
1 0 0 0 35
1 0 0 1 39
1 0 1 0 43
1 0 1 1 47
1 1 0 0 51
1 1 0 1 55
1 1 1 0 59
1 1 1 1 63
F4
0
1
1
M3 M2 M1
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
F3
0
1
F2
0
1
F1
0
1
DB20 DB19 DB18 DB17 DB16 DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6
DB5 DB4 DB3 DB2 DB1 DB0
C2 (1) C1 (1)
F1
PD1
M1
M2M3F3P1P2 CPI1CPI2CPI5
CPI6
TC4PD2 F2
CPI3CPI4
DB21
TC3 TC2 TC1
DB22DB23
F4
F5
THREE-STATE
F5
X
0
1
NEGATIVE
POSITIVE
PRESCALER
VALUE
POWER-
DOWN 2
CURRENT
SETTING
2
CURRENT
SETTING
1
TIMER COUNTER
CONTROL
FASTLOCK
MODE
FASTLOCK
ENABLE
CP THREE-
STATE
MUXOUT
CONTROL
POWER-
DOWN 1
COUNTER
RESET
CONTROL
BITS
PHASE DETECTOR
POLARITY
COUNTER
OPERATION
NORMAL
R, A, B COUNTERS
HELD IN RESET
CHARGE PUMP
OUTPUT
NORMAL
FASTLOCK DISABLED
FASTLOCK MODE 1
FASTLOCK MODE 2
FASTLOCK MODE
THREE-STATE OUTPUT
DIGITAL LOCK DETECT
(ACTIVE HIGH)
N DIVIDER OUTPUT
DV
DD
R DIVIDER OUTPUT
N-CHANNEL OPEN-DRAIN
LOCK DETECT
SERIAL DATA OUTPUT
DGND
OUTPUT
TIMEOUT
(PFD CYCLES)
I
CP
(mA)
ASYNCHRONOUS POWER-DOWN
NORMAL OPERATION
ASYNCHRONOUS POWER-DOWN
SYNCHRONOUS POWER-DOWN
CE PIN
PRESCALER VALUE
PD
POLARITY
02720-026