Datasheet
Data Sheet ADE9153A
Rev. 0 | Page 3 of 50
SPECIFICATIONS
VDD = 2.97 V to 3.63 V, AGND = DGND = 0 V, on-chip reference, CLKIN = 12.288 MHz, T
MIN
to T
MAX
= −40°C to +85°C, and T
A
= 25°C
(typical), unless otherwise noted.
Table 1.
Parameter Min Typ Max Unit Test Conditions/Comments
ACCURACY (MEASUREMENT ERROR
PER PHASE)
Percentage of the typical value derived from comparing
the actual value with the typical-based expected values
when a 10:1 signal is applied
Total Active Energy 0.1 %
Over a dynamic range of 3000 to 1, 10 sec accumulation
programmable gain amplifier (PGA), AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 10,000 to 1, 30 sec
accumulation; AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
Fundamental Reactive Energy 0.1 %
Over a dynamic range of 3000 to 1, 10 sec accumulation;
AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 10,000 to 1, 30 sec
accumulation AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
Total Apparent Energy 0.1 %
Over a dynamic range of 1000 to 1, 1 sec accumulation;
AI_PGAGAIN = 16×
0.2 % AI_PGAGAIN = 38.4×
0.25 %
Over a dynamic range of 3000 to 1, 10 sec accumulation
AI_PGAGAIN = 16×
0.5 % AI_PGAGAIN = 38.4×
RMS Current (I
RMS
) and Apparent
Power (VA)
0.1 %
Over a dynamic range of 1000 to 1, 1 sec (averaging)
AI_PGAGAIN = 16×, BI_PGAGAIN = 1×
0.2 %
Over a dynamic range of 1000 to 1, 1 sec (averaging),
AI_PGAGAIN = 38.4×
0.3 %
Over a dynamic range of 3000 to 1, 1 sec (averaging),
AI_PGAGAIN = 16×, BI_PGAGAIN = 1×
0.6 %
Over a dynamic range of 3000 to 1, 1 sec (averaging),
AI_PGAGAIN = 38.4×
RMS Voltage (V
RMS
) 0.2 % Over a dynamic range of 1000 to 1, 1 sec (averaging)
Active Power (WATT), Fundamental
Reactive Power (VAR)
0.25 %
Over a dynamic range of 3000 to 1, 1 sec, AI_PGAGAIN =
16×
0.5 %
Over a dynamic range of 3000 to 1, 1 sec, AI_PGAGAIN =
38.4×
One Cycle RMS Current and Voltage
Refreshed Each Half Cycle
0.5 %
Over a dynamic range of 500 to 1 on current and 250 to
1 on voltage
1 %
Over a dynamic range of 1000 to 1 on current and 500 to
1 on voltage
Line Period Measurement 0.001 Hz Resolution at 50 Hz
Voltage to Current Angle
Measurement
0.036 Degrees Resolution at 50 Hz