SPECIFICATIONS
VDD = 3.3 V ± 10%, AGND = DGND = 0 V, on-chip reference, CLKIN = 16.384 MHz, T
MIN
to T
MAX
= −40°C to +85°C.
Table 1.
Parameter
1, 2
Min Typ Max Unit Test Conditions/Comments
ACTIVE ENERGY MEASUREMENT
Active Energy Measurement Error
(per Phase)
Total Active Energy 0.1 % Over a dynamic range of 1000 to 1,
PGA = 1, 2, 4; integrator off, pf = 1, gain
compensation only
0.2 % Over a dynamic range of 5000 to 1,
PGA = 1, 2, 4; integrator off, pf = 1
0.1 % Over a dynamic range of 500 to 1,
PGA = 8, 16; integrator on, pf = 1, gain
compensation only
0.2 % Over a dynamic range of 2000 to 1,
PGA = 8, 16; integrator on, pf = 1
Fundamental Active Energy 0.1 % Over a dynamic range of 1000 to 1,
PGA = 1, 2, 4; integrator off, pf = 1, gain
compensation only
0.2 % Over a dynamic range of 5000 to 1,
PGA = 1, 2, 4; integrator off, pf = 1
0.1 % Over a dynamic range of 500 to 1,
PGA = 8, 16; integrator on, pf = 1, gain
compensation only
0.2 % Over a dynamic range of 2000 to 1,
PGA = 8, 16; integrator on, pf = 1
Phase Error Between Channels Line frequency = 45 Hz to 65 Hz, HPF on
Power Factor (PF) = 0.8 Capacitive ±0.05 Degrees Phase lead 37°
PF = 0.5 Inductive ±0.05 Degrees Phase lag 60°
AC Power Supply Rejection VDD = 3.3 V + 120 mV rms/120 Hz,
IPx = VPx = ±100 mV rms
Output Frequency Variation 0.01 %
DC Power Supply Rejection VDD = 3.3 V ± 330 mV dc
Output Frequency Variation 0.01 %
Total Active Energy Measurement
Bandwidth (−3 dB)
3.3 kHz
REACTIVE ENERGY MEASUREMENT
Reactive Energy Measurement Error
(per Phase)
Fundamental Reactive Energy 0.1 % Over a dynamic range of 1000 to 1,
PGA = 1, 2, 4; integrator off, pf = 0, gain
compensation only
0.2 % Over a dynamic range of 5000 to 1,
PGA = 1, 2, 4; integrator off, pf = 0
0.1 % Over a dynamic range of 500 to 1,
PGA = 8, 16; integrator on, pf = 0, gain
compensation only
0.2 % Over a dynamic range of 2000 to 1,
PGA = 8, 16; integrator on, pf = 0
Phase Error Between Channels Line frequency = 45 Hz to 65 Hz, HPF on
PF = 0.8 Capacitive ±0.05 Degrees Phase lead 37°
PF = 0.5 Inductive ±0.05 Degrees Phase lag 60°
AC Power Supply Rejection VDD = 3.3 V + 120 mV rms/120 Hz,
IPx = VPx = ± 100 mV rms
Output Frequency Variation 0.01 %
DC Power Supply Rejection VDD = 3.3 V ± 330 mV dc