Datasheet
Table Of Contents
- FEATURES
- GENERAL DESCRIPTION
- FUNCTIONAL BLOCK DIAGRAM
- SPECIFICATIONS
- TIMING CHARACTERISTICS
- ABSOLUTE MAXIMUM RATINGS
- ORDERING GUIDE
- PIN CONFIGURATION
- PIN FUNCTION DESCRIPTIONS
- Typical Performance Characteristics
- TERMINOLOGY
- POWER SUPPLY MONITOR
- ANALOG INPUTS
- ANALOG-TO-DIGITAL CONVERSION
- CURRENT CHANNEL ADC
- VOLTAGE CHANNEL ADC
- ZERO-CROSSING DETECTION
- PERIOD MEASUREMENT
- LINE VOLTAGE SAG DETECTION
- PEAK DETECTION
- TEMPERATURE MEASUREMENT
- PHASE COMPENSATION
- ROOT MEAN SQUARE MEASUREMENT
- ACTIVE POWER CALCULATION
- TOTAL ACTIVE POWER CALCULATION
- ENERGY CALCULATION
- LINE ENERGY ACCUMULATION
- REACTIVE POWER CALCULATION
- TOTAL REACTIVE POWER CALCULATION
- APPARENT POWER CALCULATION
- TOTAL APPARENT POWER CALCULATION
- APPARENT ENERGY CALCULATION
- LINE APPARENT ENERGY ACCUMULATION
- ENERGIES SCALING
- CHECK SUM REGISTER
- SERIAL INTERFACE
- INTERRUPTS
- ACCESSING THE ADE7754 ON-CHIP REGISTERS
- OUTLINE DIMENSIONS

REV. 0
Typical Performance Characteristics–ADE7754
–7–
CURRENT (% fs)
PERCENT ERROR
0.00
0.10
0.20
0.30
0.40
0.50
–0.40
–0.30
–0.20
–0.10
–0.50
0.01 0.1 1 10 100
PHASE A
PHASE B
PHASE C
PHASE A + B + C
WYE CONNECTION
GAIN = 1
PF = 1
INTERNAL REFERENCE
TPC 1. Real Power Error as a Percentage of
Reading with Gain = 1 and Internal Reference
(WYE Connection)
CURRENT (% fs)
PERCENT ERROR
0.50
0.20
0.30
0.40
0.00
0.10
–0.30
–0.20
–0.10
–0.50
–0.40
0.01 0.1 1 10 100
PF = +1
PF = +0.5
PF = –0.5
DELTA CONNECTION
GAIN = 1
PF = 0.5
INTERNAL REFERENCE
TPC 2. Real Power Error as a Percentage of
Reading over Power Factor with Internal
Reference (DELTA Connection)
CURRENT (% fs)
PERCENT ERROR
1.00
0.00
–0.20
–0.60
–0.40
–1.00
–0.80
0.01 0.1 1 10 100
0.20
0.40
0.60
0.80
GAIN = 1
PF = 0.5
INTERNAL REFERENCE
+85∞C PF = +0.5
+25∞C PF = –0.5
+25∞C PF = +1.0
–40∞C PF = +0.5
TPC 3. Real Power Error as a
Percentage
of Reading
over Power Factor with Internal Reference (Gain = 1)
CURRENT INPUT (% fs)
PERCENT ERROR
1.00
–1.00
110100
–0.80
–0.60
–0.40
–0.20
0.00
0.20
0.40
0.60
0.80
GAIN = 1
INTERNAL REFERENCE
TPC 4.
Current RMS Error as a Percentage of
Reading with Internal Reference (Gain = 1)
VOLTAGE INPUT (% fs)
PERCENT ERROR
0.50
0.00
–0.50
110100
–0.40
–0.30
–0.20
–0.10
0.10
0.20
0.30
0.40
GAIN = 1
INTERNAL REFERENCE
TPC 5. Voltage RMS Error as a Percentage of
Reading with Internal Reference (Gain = 1)
VOLTAGE INPUT (% fs)
PERCENT ERROR
0.50
0.00
–0.50
0.01 0.1 1 10 100
–0.40
–0.30
–0.20
–0.10
0.10
0.20
0.30
0.40
GAIN = 1
PF = 0.5
EXTERNAL REFERENCE
+25∞C PF = –0.5
–40∞C PF = +0.5
+85∞C PF = +0.5+25∞C PF = +1
TPC 6. Real Power Error as a Percentage of Reading
over Power Factor with External Reference (Gain = 1)