Datasheet

ADE5166/ADE5169/ADE5566/ADE5569 Data Sheet
Rev. D | Page 44 of 156
Table 35. Waveform Mode Register (WAVMODE, Address 0x0D)
Bit Mnemonic Default Description
[7:5] WAV2SEL 000 Waveform Sample 2 selection for samples mode.
WAV2SEL Source
000 Current
001 Voltage
010 Active power multiplier output
011 Reactive power multiplier output
1
100 VA multiplier output
101 I
rms
LPF output (low 24-bit)
110, 111 Reserved
[4:2] WAV1SEL 000 Waveform Sample 1 selection for samples mode.
WAV1SEL Source
000 Current
001 Voltage
010 Active power multiplier output
011 Reactive power multiplier output
1
100 VA multiplier output
101
I
rms
LPF output (low 24-bit)
110, 111 Reserved
[1:0] DTRT 00 Waveform samples output data rate.
DTRT Update Rate (Clock = f
CORE
/5 = 819.2 kHz)
00 25.6 kSPS (clock/32)
01 12.8 kSPS (clock/64)
10 6.4 kSPS (clock/128)
11 3.2 kSPS (clock/256)
1
This function is not available in the ADE5166 and ADE5566.
Table 36. No Load Configuration Register (NLMODE, Address 0x0E)
Bit Mnemonic Default Description
7
DISVARCMP
1
0
Setting this bit disables fundamental var gain compensation over line frequency.
6 IRMSNOLOAD 0 Logic 1 enables I
rms
no load threshold detection. The level is defined by the setting of the
VANOLOAD bits.
[5:4] VANOLOAD 00 Apparent power no load threshold.
VANOLOAD Result
00 No load detection disabled
01 No load detection enabled with threshold = 0.030% of full scale
10 No load detection enabled with threshold = 0.015% of full scale
11 No load detection enabled with threshold = 0.0075% of full scale
[3:2] VARNOLOAD
1
00 Reactive power no load threshold.
VARNOLOAD
Result
00 No load detection disabled
01
No load detection enabled with threshold = 0.015% of full scale
10 No load detection enabled with threshold = 0.0075% of full scale
11 No load detection enabled with threshold = 0.0037% of full scale
[1:0] APNOLOAD 00 Active power no load threshold.
APNOLOAD Result
00 No load detection disabled
01 No load detection enabled with threshold = 0.015% of full scale
10 No load detection enabled with threshold = 0.0075% of full scale
11
No load detection enabled with threshold = 0.0037% of full scale
1
This function is not available in the ADE5166 and ADE5566.