Datasheet
ADA4410-6
Rev. B | Page 4 of 16
Parameter Test Conditions/Comments Min Typ Max Unit
POWER SUPPLY
Operating Range 4.5 12 V
Quiescent Current 82 88 mA
Quiescent Current—Disabled 15 150 μA
PSRR, Positive Supply All channels except CV 62 72 dB
CV channel 59 66 dB
PSRR, Negative Supply All channels except CV 55 62 dB
CV channel 52 56 dB