Datasheet
AD9923A
Rev. A | Page 61 of 84
Table 44. Standby Mode Operation—Vertical and Shutter Outputs
Output Standby 3 (Default)
1, 2
OUTCONTROL = Low Standby 2
3, 4
Standby 1
3, 4
XV1 Low Low Low Low
XV2 Low Low Low Low
XV3 Low Low Low Low
XV4 Low Low Low Low
XV5 Low Low Low Low
XV6 Low Low Low Low
XV7 Low Low Low Low
XV8 Low Low Low Low
XV9 Low Low Low Low
XV10 Low Low Low Low
XV11 Low Low Low Low
XV12 Low Low Low Low
XV13 Low Low Low Low
VSG1 Low High High High
VSG2 Low High High High
VSG3 Low High High High
VSG4 Low High High High
VSG5 Low High High High
VSG6 Low High High High
VSG7 Low High High High
VSG8 Low High High High
XSUBCK Low High High High
VSUB
5
Low Low Low Low
MSHUT
5
Low Low Low Low
STROBE
5
Low Low Low Low
1
Polarities for vertical and shutter outputs when the AD9923 is in Standby 3 mode are programmable using the STANDBY3POL register, Address 0xE2 (default register
value = 0x000000).
2
Bit assignments for the STANDBY3POL[23:0] register (Address 0xE2): (MSB) STROBE, MSHUT, VSUB, XSUBCK, VSG8, VSG7, VSG6, VSG3, VSG5, VSG4, VSG2, VSG1, XV13,
XV12, XV11, XV10, XV9, XV8, XV7, XV6, XV5, XV4, XV3, XV2, and XV1 (LSB).
3
Polarities for vertical outputs when the AD9923 is in Standby 1, Standby 2, or if OUTCONTROL = low, are programmable using the STANDBY12POL register,
Address 0xF3 (default register value = 0x3FE000)
4
Bit assignments for the STANDBY12POL[20:0] register (Address 0xF3): (MSB) XSUBCK, VSG8, VSG7, VSG6, VSG3, VSG5, VSG4, VSG2, VSG1, XV13, XV12, XV11, XV10, XV9,
XV8, XV7, XV6, XV5, XV4, XV3, XV2, and XV1 (LSB).
5
VSUB, MSHUT, and STROBE polarities for Standby 1, Standby 2, or if OUTCONTROL = low are controlled by STANDBY3POL.