COMPLETE REGISTER LISTING
When an address contains fewer than 28 data bits, all remaining bits must be written as 0s.
Table 52. AFE Registers
Address
Data
Bits
Default
Value
Default
Update
Type
Name Description
0x00 [1:0] 0x03 SCK STANDBY Standby modes.
0 = normal operation (full power).
1 = Standby1 mode.
2 = Standby2 mode.
3 = Standby3 mode (lowest power).
[2] 0x01 CLPENABLE 0 = disable OB clamp.
1 = enable OB clamp.
[3] 0 CLPSPEED 0 = select normal OB clamp settling.
1 = select fast OB clamp settling.
[4] 0 FASTUPDATE 0 = ignore CDS gain.
1 = very fast clamping when CDS gain is updated.
[5] 0 PBLK_LVL 0 = blank data outputs to 0 during PBLK.
1 = blank data outputs to programmed clamp level during PBLK.
[6] 0 DCBYP 0 = enable input dc restore circuit during PBLK.
1 = disable input dc restore circuit during PBLK.
0x01 [0] 0 SCK DOUTDISABLE 0 = data outputs are driven.
1 = data outputs are three-stated.
[1] 0 DOUTLATCH 0 = latch data outputs using DOUTPHASE register setting.
1 = output latch is transparent.
[2] 0 GRAYEN 1 = enable gray coding of digital data output.
[3] 0 Test Set to 0.
0x02 [0] 0 VD Test Do not access, or set to 0.
0x03 [23:0] 0xFFFFFF VD Test Do not access, or set to 0xFFFFFF.
0x04 [2:0] 0 VD CDSGAIN CDS gain setting.
0 = −3 dB.
4 = 0 dB.
6 = +3 dB.
7 = +6 dB.
All other values are invalid.
0x05 [9:0] 0x0F VD VGAGAIN VGA gain. 6 dB to 42 dB (0.035 dB per step).
0x06 [9:0] 0x1EC VD CLAMPLEVEL Optical black clamp level. 0 LSB to 255 LSB (0.25 LSB per step).
0x07 [27:0] 0 VD Test Do not access, or set to 0.
0x08 [27:0] 0 VD Test Do not access, or set to 0.
0x09 [27:0] 0 VD Test Do not access, or set to 0.
0x0A [27:0] 0 VD Test Do not access, or set to 0.
0x0B [27:0] 0 SCK UNUSED Do not access, or set to 0.
0x0C [27:0] 0 SCK Test Do not access, or set to 0.
0x0D [0] 0 VD CLIDIVIDE 0 = do not divide CLI frequency.
1 = divide CLI frequency by 2.
[7:1] 0 Test Do not access, or set to 0.
0x0E [7:0] 0 SCK Test Set to 0.
[8] 0 VDHD_IE VD/HD input enable. Set to 1 to enable VD/HD inputs for slave mode.
0x0F [27:0] 0 VD Test Set to 0.