Datasheet
REV. A
AD9848/AD9849
–7–
ABSOLUTE MAXIMUM RATINGS
With
Parameter Respect To Min Max Unit
AVDD1, 2, 3 AVSS –0.3 +3.9 V
DVDD1, DVDD2 (AD9848) DVSS –0.3 +3.9 V
DVDD1, DVDD2 (AD9849) DVSS –0.3 +5.5 V
DVDD3, 4 DVSS –0.3 +3.9 V
Digital Outputs DVSS3 –0.3 DVDD3 + 0.3 V
CLPOB, CLPDM, BLK DVSS4 –0.3 DVDD4 + 0.3 V
CLI AVSS –0.3 AVDD + 0.3 V
SCK, SL, SDATA DVSS4 –0.3 DVDD4 + 0.3 V
VRT, VRB AVSS –0.3 AVDD + 0.3 V
BYP1–3, CCDIN AVSS –0.3 AVDD + 0.3 V
Junction Temperature 150 °C
Lead Temperature (10 sec) 300 °C
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD9848/AD9849 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
THERMAL CHARACTERISTICS
Thermal Resistance
48-Lead LQFP Package
JA
= 92°C
ORDERING GUIDE
Temperature Package Package
Model Range Description Option
AD9848AKST –20°C to +85°CThin Plastic Quad ST-48
Flatpack (LQFP)
AD9849AKST –20°C to +85°CThin Plastic Quad ST-48
Flatpack (LQFP)