AD9848/AD9849
–22–
UP TO FOUR INDIVIDUAL HORIZONTAL CLAMP AND BLANKING REGIONS MAY BE
PROGRAMMED WITHIN A SINGLE FIELD, USING THE SEQUENCE CHANGE POSITIONS.
SEQUENCE CHANGE OF POSITION #1
SEQUENCE CHANGE OF POSITION #2
SEQUENCE CHANGE OF POSITION #3
SINGLE FIELD (1 VD INTERVAL)
CLAMP AND PBLK SEQUENCE REGION 0
SEQUENCE CHANGE OF POSITION #0
(V-COUNTER = 0)
CLAMP AND PBLK SEQUENCE REGION 3
CLAMP AND PBLK SEQUENCE REGION 2
CLAMP AND PBLK SEQUENCE REGION 1
Figure 12. Clamp and Blanking Sequence Flexibility
Table IV. CLPOB, CLPDM, PBLK Individual Sequence Parameters
Register Name Length Range Description
SPOL 1b High/Low Starting Polarity of Clamp and Blanking Pulses for Sequences 0–3
TOG1 12b 0–4095 Pixel Location First Toggle Position within the Line for Sequences 0–3
TOG2 12b 0–4095 Pixel Location Second Toggle Position within the Line for Sequences 0–3
Table V. HBLK Individual Sequence Parameters
Register Name Length Range Description
HBLKMASK 1b High/Low Masking Polarity for H1 for Sequences 0–3 (0 = H1 Low, 1 = H1 High)
HBLKTOG1 12b 0–4095 Pixel Location First Toggle Position within the Line for Sequences 0–3
HBLKTOG2 12b 0–4095 Pixel Location Second Toggle Position within the Line for Sequences 0–3
Table VI. Horizontal Sequence Control Parameters for CLPOB, CLPDM, PBLK, and HBLK
Register Name Length Range Description
SCP1–SCP3 12b 0–4095 Line Number CLAMP/BLANK SCP to Define Horizontal Regions 0–3
SPTR0–SPTR3 2b 0–3 Sequence Number Sequence Pointer for Horizontal Regions 0–3
H-Counter Synchronization
The H-Counter reset occurs on the sixth CLI rising edge following the HD falling edge. The PxGA steering is synchronized with the
reset of the internal H-Counter (see Figure 13).
000 1 12111 0 031100
012345678910111214150123
023
4
H-COUNTER
RESET
VD
NOTES
1. INTERNAL H-COUNTER IS RESET ON THE SIXTH CLI RISING EDGE FOLLOWING THE HD FALLING EDGE.
2. PxGA STEERING IS SYNCRONIZED WITH THE RESET OF THE INTERNAL H-COUNTER (MOSAIC SEPARATE MODE IS SHOWN).
3. VD FALLING EDGE SHOULD OCCUR ONE CLOCK CYCLE BEFORE HD FALLING EDGE FOR PROPER PxGA LINE SYNCHRONIZATION.
HD
XXXXXXX
PxGA GAIN
REGISTER
CLI
XXXXXXX
H-COUNTER
(PIXEL COUNTER)
3ns MIN
23
5
3ns MIN
X
X
Figure 13. H-Counter Synchronization