Datasheet
Data Sheet AD9559
Rev. C | Page 7 of 120
REFERENCE MONITORS
Table 6.
Parameter Min Typ Max Unit Test Conditions/Comments
REFERENCE MONITORS
Reference Monitor
Loss of Reference Detection Time 1.15 DPLL PFD
period
Nominal phase detector period = R/f
REF
1
Frequency Out-of Range Limits 2 10
5
Δf/f
REF
(ppm)
Programmable (lower bound subject to quality
of the system clock (SYSCLK)); SYSCLK accuracy
must be less than the lower bound
Validation Timer 0.001 65.535 sec Programmable in 1 ms increments
1
f
REF
is the frequency of the active reference; R is the frequency division factor determined by the R divider.
REFERENCE SWITCHOVER SPECIFICATIONS
Table 7.
Parameter Min Typ Max Unit Test Conditions/Comments
REFERENCE SWITCHOVER SPECIFICATIONS
Maximum Output Phase Perturbation
(Phase Build-Out Switchover)
Assumes a jitter-free reference; satisfies
Telcordia GR-1244-CORE requirements;
base loop filter selection bit set to 1b for
all active references
50 Hz DPLL Loop Bandwidth Test conditions: 19.44 MHz to 174.70308 MHz;
DPLL BW = 50 Hz; 49.152 MHz signal generator
used for system clock source
Peak ±55 ±100 ps
Steady State ±55 ±100 ps
Time Required to Switch to a New Reference
Phase Build-Out Switchover
10
DPLL PFD
period
Calculated using the nominal phase detector
period (NPDP = R/f
REF
); the total time required
is the time plus the reference validation time,
plus the time required to lock to the new
reference