SPECIFICATIONS
Minimum (min) and maximum (max) values apply for the full range of supply voltage and operating temperature variations. Typical (typ)
values apply for VDD3 = 3.3 V; VDD = 1.8 V; T
A
= 25°C, unless otherwise noted.
SUPPLY VOLTAGE
Table 1.
Parameter Min Typ Max Unit Test Conditions/Comments
SUPPLY VOLTAGE
VDD3 3.135 3.30 3.465 V
VDD 1.71 1.80 1.89 V
SUPPLY CURRENT
The test conditions for the maximum (max) supply current are at the maximum supply voltage found in Table 1.
The test conditions for the typical (typ) supply current are at the typical supply voltage found in Table 1.
The test conditions for the minimum (min) supply current are at the minimum supply voltage found in Table 1.
Table 2.
Parameter Min Typ Max Unit Test Conditions/Comments
SUPPLY CURRENT FOR TYPICAL CONFIGURATION Typical values are for the Typical Configuration
parameter listed in Table 3
I
VDD3
34 42 50 mA
I
VDD
253 316 380 mA
SUPPLY CURRENT FOR ALL BLOCKS RUNNING
CONFIGURATION
Maximum values are for the All Blocks Running
parameter listed in Table 3
I
VDD3
75 94 113 mA
I
VDD
256 320 384 mA