Datasheet
AD9553   
Rev. A | Page 22 of 44 
00
11
10
01
REG 0x29[7:6]
REVERTIVE
NON-REVERTIVE
SELECT REFA
SELECT REFB
REVERTIVE/
NON-REVERTIVE
LOGIC
SPI SELECT REFA/B
LOGIC
SEL
REFB
FROM REFA
INPUT
FROM REFB
INPUT
FROM XTAL
INPUT
SIGNAL
DETECTOR
REFA PRESENT
REFB PRESENT
XTAL PRESENT
REFA/B
SELECTION LOGIC
MUX
CONTROL
LOGIC
TO
PLL
SEL B/A
SEL B/A
SEL B/A
SEL B/A
11
FDBK
CLOCK
MUX
R
A
 DIVIDER
÷
÷
÷
R
B
 DIVIDER
R
XO
 DIVIDER
08565-102
Figure 29. Switchover/Holdover Block Diagram 
The user can override the automatic switchover functions 
(revertive and nonrevertive) and manually select the REFA  
or REFB signal by programming Register 0x29[7:6] = 10 or 11, 
respectively. Note, however, that the desired signal (REFA or 
REFB) must be present for the device to select it. 
The user can also force the device to switch to REFB by applying 
a Logic 1 to the external SEL REFB pin. This overrides a REFA 
selection invoked by either the revertive/nonrevertive logic or 
when Register 0x29[7:6] = 10. Note, however, that REFB must 
be present to be selected by the device. 
PLL (PFD, Charge Pump, VCO, Feedback Divider) 
The PLL (see Figure 27) consists of a phase/frequency detector 
(PFD), a partially integrated analog loop filter (see Figure 30), 
an integrated voltage controlled oscillator (VCO), and a 20-bit 
programmable feedback divider. The PLL generates a 3.35 GHz 
to 4.05 GHz clock signal that is phase locked to the active input 
reference signal, and its frequency is the phase detector frequency 
(FPFD) multiplied by the feedback divider value (N). 
The PFD of the PLL drives a charge pump that increases, decreases, 
or holds constant the charge stored on the loop filter capacitors 
(both internal and external). The stored charge results in a voltage 
that sets the output frequency of the VCO. The feedback loop of 
the PLL causes the VCO control voltage to vary in such a way as 
to phase lock the PFD input signals. Note that the PFD supports 
input frequencies spanning 13.3 kHz to 100 MHz (implying that 
input frequencies between 8 kHz and 13.3 kHz must use the ×2 
frequency multiplier in the input path).  
The PLL has a VCO with 128 frequency bands spanning a range 
of 3350 MHz to 4050 MHz (3700 MHz nominal). However, the 
actual operating frequency within a particular band depends on 
the control voltage that appears on the loop filter capacitor. The 
control voltage causes the VCO output frequency to vary linearly 
within the selected band. This frequency variability allows the 
control loop of the PLL to synchronize the VCO output signal 
with the reference signal applied to the PFD.  
Typically, selection of the VCO frequency band (as well as gain 
adjustment) occurs automatically as part of the automatic VCO 
calibration process of the device, which initiates at power up (or 
reset). Alternatively, the user can force VCO calibration by first 
enabling SPI control of VCO calibration (Register 0x0E[2] = 1) 
and then writing a 1 to the calibrate VCO bit (Register 0x0E[7]). 
Note that VCO calibration centers the dc operating point of the 
VCO control signal. Furthermore, during VCO calibration, the 
output drivers provide a static dc signal. 
To facilitate system debugging, the user can override the VCO band 
setting by first enabling SPI control of VCO band (Register 0x0E[0] 
= 1) and then writing the desired value to Register 0x10[7:1]. 
The feedback divider (N-divider) sets the frequency multi-
plication factor of the PLL in integer steps over a 20-bit range. 
Note that the N-divider has a lower limit of 32. 