Table 36 to Table 39 show the output duty cycle for various configurations of the channel divider and VCO divider.
Table 36. Channel Divider Output Duty Cycle with VCO Divider ≠ 1; Input Duty Cycle Is 50%
VCO Divider
D
X
Output Duty Cycle
N + M + 2 Disable Divider x DCC = 1b Disable Divider x DCC = 0b
Even Channel divider bypassed 50% 50%
Odd = 3 Channel divider bypassed 33.3% 50%
Odd = 5 Channel divider bypassed 40% 50%
Even, odd Even (N + 1)/(N + M + 2) 50%, requires M = N
Even, odd Odd (N + 1)/(N + M + 2) 50%, requires M = N + 1
Table 37. Channel Divider Output Duty Cycle with VCO Divider ≠ 1; Input Duty Cycle Is X%
VCO Divider
D
X
Output Duty Cycle
N + M + 2 Disable Divider x DCC = 1b Disable Divider x DCC = 0b
Even
Channel divider bypassed
50%
50%
Odd = 3 Channel divider bypassed 33.3% (1 + X%)/3
Odd = 5 Channel divider bypassed 40% (2 + X%)/5
Even Even (N + 1)/(N + M + 2) 50%, requires M = N
Even Odd (N + 1)/(N + M + 2) 50%, requires M = N + 1
Odd = 3 Even (N + 1)/(N + M + 2) 50%, requires M = N
Odd = 3 Odd (N + 1)/(N + M + 2) (3N + 4 + X%)/(6N + 9), requires M = N + 1
Odd = 5 Even (N + 1)/(N + M + 2) 50%, requires M = N
Odd = 5 Odd (N + 1)/(N + M + 2) (5N + 7 + X%)/(10N + 15), requires M = N + 1
Table 38. Channel Divider Output Duty Cycle When the VCO Divider Is Enabled and Set to 1
Input Clock
Duty Cycle
D
X
Output Duty Cycle
N + M + 2 Disable Divider x DCC = 1b Disable Divider x DCC = 0b
Any Even (N + 1)/(M + N + 2) 50%, requires M = N
50% Odd (N + 1)/(M + N + 2) 50%, requires M = N + 1
X% Odd (N + 1)/(M + N + 2) (N + 1 + X%)/(2 × N + 3), requires M = N + 1
The channel divider must be enabled when the VCO divider = 1.
Table 39. Channel Divider Output Duty Cycle When the VCO Divider Is Bypassed
Input Clock
Duty Cycle
D
X
Output Duty Cycle
N + M + 2
Disable Divider x DCC = 1b
Disable Divider x DCC = 0b
Any Channel divider bypassed Same as input duty cycle Same as input duty cycle
Any Even (N + 1)/(M + N + 2) 50%, requires M = N
50% Odd (N + 1)/(M + N + 2) 50%, requires M = N + 1
X% Odd (N + 1)/(M + N + 2) (N + 1 + X%)/(2 × N + 3), requires M = N + 1
The internal VCO has a duty cycle of 50%. Therefore, when the
VCO is connected directly to the output, the duty cycle is 50%.
If the CLK input is routed directly to the output, the duty cycle of
the output is the same as the CLK input.
Phase Offset or Coarse Time Delay
Each channel divider allows for a phase offset or a coarse time
delay to be programmed by setting register bits (see Table 40).
These settings determine the number of cycles (successive rising
edges) of the channel divider input frequency by which to offset,
or delay, the rising edge of the output of the divider. This delay
is with respect to a nondelayed output (that is, with a phase offset
of zero). The amount of the delay is set by five bits loaded into
the phase offset (PO) register plus the start high (SH) bit for
each channel divider.
When the start high bit is set, the delay is also affected by the
number of low cycles (M) programmed for the divider.
The SYNC function must be used to make phase offsets effective
(see the Synchronizing the Outputs—SYNC Function section).
Table 40. Setting Phase Offset and Division
Divider
Start
High
(SH) Bits
Phase
Offset
(PO) Bits
Low Cycles,
M Value Bits
High Cycles,
N Value Bits
0 0x191[4] 0x191[3:0] 0x190[7:4] 0x190[3:0]
1 0x194[4] 0x194[3:0] 0x193[7:4] 0x193[3:0]
2 0x197[4] 0x197[3:0] 0x196[7:4] 0x196[3:0]
3 0x19A[4] 0x19A[3:0] 0x199[7:4] 0x199[3:0]