Datasheet

Data Sheet AD9228
Rev. E | Page 27 of 56
Two output clocks are provided to assist in capturing data from
the AD9228. The DCO is used to clock the output data and is
equal to six times the sample clock (CLK) rate. Data is clocked
out of the AD9228 and must be captured on the rising and
falling edges of the DCO that supports double data rate (DDR)
capturing. The FCO is used to signal the start of a new output
byte and is equal to the sample clock rate. See the timing
diagram shown in Figure 2 for more information.
Table 9. Flexible Output Test Modes
Output Test Mode
Bit Sequence Pattern Name Digital Output Word 1 Digital Output Word 2
Subject to Data
Format Select
0000 Off (default) N/A N/A N/A
0001 Midscale short
1000 0000 (8-bit)
10 0000 0000 (10-bit)
1000 0000 0000 (12-bit)
10 0000 0000 0000 (14-bit)
Same Yes
0010 +Full-scale short
1111 1111 (8-bit)
11 1111 1111 (10-bit)
1111 1111 1111 (12-bit)
11 1111 1111 1111 (14-bit)
Same Yes
0011 −Full-scale short
0000 0000 (8-bit)
00 0000 0000 (10-bit)
0000 0000 0000 (12-bit)
00 0000 0000 0000 (14-bit)
Same Yes
0100 Checkerboard
1010 1010 (8-bit)
10 1010 1010 (10-bit)
1010 1010 1010 (12-bit)
10 1010 1010 1010 (14-bit)
0101 0101 (8-bit)
01 0101 0101 (10-bit)
0101 0101 0101 (12-bit)
01 0101 0101 0101 (14-bit)
No
0101 PN sequence long
1
N/A N/A Yes
0110 PN sequence short
1
N/A N/A Yes
0111 One-/zero-word toggle
1111 1111 (8-bit)
11 1111 1111 (10-bit)
1111 1111 1111 (12-bit)
11 1111 1111 1111 (14-bit)
0000 0000 (8-bit)
00 0000 0000 (10-bit)
0000 0000 0000 (12-bit)
00 0000 0000 0000 (14-bit)
No
1000 User input Register 0x19 to Register 0x1A Register 0x1B to Register 0x1C No
1001 1-/0-bit toggle
1010 1010 (8-bit)
10 1010 1010 (10-bit)
1010 1010 1010 (12-bit)
10 1010 1010 1010 (14-bit)
N/A No
1010 1× sync
0000 1111 (8-bit)
00 0001 1111 (10-bit)
0000 0011 1111 (12-bit)
00 0000 0111 1111 (14-bit)
N/A No
1011 One bit high
1000 0000 (8-bit)
10 0000 0000 (10-bit)
1000 0000 0000 (12-bit)
10 0000 0000 0000 (14-bit)
N/A No
1100 Mixed frequency
1010 0011 (8-bit)
10 0110 0011 (10-bit)
1010 0011 0011 (12-bit)
10 1000 0110 0111 (14-bit)
N/A No
1