Datasheet

AD9216
Rev. A | Page 8 of 40
ABSOLUTE MAXIMUM RATINGS
Table 5.
Parameter To Rating
ELECTRICAL
AVDD AGND
−0.3 V to
+3.9 V
DRVDD DRGND
−0.3 V to
+3.9 V
AGND DRGND
−0.3 V to
+0.3 V
AVDD DRVDD
−0.3 V to
+3.9 V
Digital Outputs DRGND
−0.3 V to
DRVDD +
0.3 V
CLK_A, CLK_B, DCS, DFS, MUX_SELECT,
OEB_A, OEB_B, SHARED_REF,
PDWN_A, PDWN_B
AGND
−0.3 V to
AVDD +
0.3 V
VIN_A, VIN+_A, VIN_B, VIN+_B
AGND
−0.3 V to
AVDD +
0.3 V
REFT_A, REFB_A,VREF, REFT_B, REFB_B,
SENSE
AGND
−0.3 V to
AVDD +
0.3 V
ENVIRONMENTAL
1
Operating Temperature
−40°C to
+85°C
Junction Temperature 150°C
Lead Temperature (10 sec) 300°C
Storage Temperature
−65°C to
+150°C
1
Typical thermal impedances (64-lead LFCSP); θ
JA
= 26.4°C/W. These
measurements were taken on a 4-layer board (with thermal via array) in still
air, in accordance with EIA/JESD51-7.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only and functional operation of the device at these or
any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
EXPLANATION OF TEST LEVELS
Table 6.
Test Level Description
I 100% production tested.
II
100% production tested at 25°C and sample
tested at specified temperatures.
III Sample tested only.
IV
Parameter is guaranteed by design and
characterization testing.
V Parameter is a typical value only.
VI
100% production tested at 25°C; guaranteed by
design and characterization testing for industrial
temperature range; 100% production tested at
temperature extremes for military devices.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.