Datasheet

Data Sheet AD8622/AD8624
Rev. D | Page 7 of 20
I
B
(pA)
07527-008
TEMPERATURE (°C)
–60
–50
–40
–30
–20
–10
0
–50 –25 0 25 50 75 100 125
I
B
+
I
B
V
SY
= ±2.5V
Figure 11. Input Bias Current vs. Temperature
–150
–125
–100
–75
–50
–25
0
25
50
–2.5 –1.5
–0.5 0.5 1.5 2.5
V
SY
= ±2.5V
07527-012
V
CM
(V)
I
B
(pA)
Figure 12. Input Bias Current vs. Common-Mode Voltage
10
1
0.1
0.01
0.001
0.01 0.1 1 10 100
LOAD CURRENT (mA)
OUTPUT VOLTAGE TO SUPPLY RAIL (V)
07527-013
V
SY
= ±2.5V
V
CC
– V
OH
V
OL
– V
EE
Figure 13. Output Voltage to Supply Rail vs. Load Current
07527-011
TEMPERATURE (
°C)
I
B
(pA)
–50
–40
–30
–20
–10
0
10
–50
–25
0 25
50
75
100
125
I
B
+
I
B
V
SY
= ±15V
Figure 14. Input Bias Current vs. Temperature
–60
–40
–20
0
20
40
60
–15 –10 –5 0 5 10 15
V
SY
= ±15V
07527-009
V
CM
(V)
I
B
(pA)
Figure 15. Input Bias Current vs. Common-Mode Voltage
0.01 0.1 1 10 100
LOAD CURRENT (mA)
OUTPUT VOLTAGE TO SUPPLY RAIL (V)
07527-010
V
SY
= ±15V
V
CC
– V
OH
V
OL
– V
EE
100
10
1
0.1
0.01
0.001
Figure 16. Output Voltage to Supply Rail vs. Load Current