Datasheet
AD8605/AD8606/AD8608 Data Sheet
Rev. N | Page 8 of 24
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Rating
Supply Voltage 6 V
Input Voltage GND to V
S
Differential Input Voltage 6 V
Output Short-Circuit Duration to GND Observe Derating Curves
Storage Temperature Range
All Packages −65°C to +150°C
Operating Temperature Range
All Packages −40°C to +125°C
Junction Temperature Range
All Packages
−65°C to +150°C
Lead Temperature (Soldering, 60 sec) 300°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 4.
Package Type θ
JA
1
θ
JC
Unit
5-Ball WLCSP (CB) 170 °C/W
5-Lead SOT-23 (RJ) 240 92 °C/W
8-Ball WLCSP (CB) 115 °C/W
8-Lead MSOP (RM) 206 44 °C/W
8-Lead SOIC_N (R) 157 56 °C/W
14-Lead SOIC_N (R) 105 36 °C/W
14-Lead TSSOP (RU) 148 23 °C/W
1
θ
JA
is specified for the worst-case conditions, that is, a device soldered in a
circuit board for surface-mount packages.
ESD CAUTION