Datasheet
Date Sheet AD8510/AD8512/AD8513
Rev. K | Page 7 of 21
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter Rating
Supply Voltage ±18 V
Input Voltage ±V
S
Output Short-Circuit Duration to GND Observe derating curves
Storage Temperature Range −65°C to +150°C
Operating Temperature Range −40°C to +125°C
Junction Temperature Range −65°C to +150°C
Lead Temperature (Soldering, 10 sec) 300°C
Electrostatic Discharge
(Human Body Model)
2000 V
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
Table 4. Thermal Resistance
Package Type θ
JA
1
θ
JC
Unit
8-Lead MSOP (RM) 210 45 °C/W
8-Lead SOIC_N (R) 120 43 °C/W
14-Lead SOIC_N (R) 120 36 °C/W
14-Lead TSSOP (RU) 180 35 °C/W
1
θ
JA
is specified for worst case conditions, that is, θ
JA
is specified for device
soldered in circuit board for surface-mount packages.
ESD CAUTION