Datasheet

Data Sheet AD8376
Rev. B | Page 9 of 24
75
–80
–85
–90
–95
–100
–105
–110
–115
65
–70
–75
–80
–85
–90
–95
–100
–105
HARMONIC DISTORTION HD2 (dBc)
HARMONIC DISTORTION HD3 (dBc)
40 60 80 100 120 140 160 180 200
FREQUENCY (MHz)
HD2 –4dB
HD2 0dB
HD2 +10dB
HD2 +20dB
HD3 –4dB
HD3 0dB
HD3 +10dB
HD3 +20dB
0
6725-015
Figure 16. Harmonic Distortion vs. Frequency at Four Gain Codes,
V
OUT
= 2 V p-p
80
–85
–90
–95
–100
–105
–110
–115
–120
–125
–130
60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
HARMONIC DISTORTION HD2 (dBc)
HARMONIC DISTORTION HD3 (dBc)
–5 –4 –3 –2 –1 0 1 2 3 4 5
P
OUT
(dBm)
HD3_+20dB
HD3_+10dB
HD3_0dB
HD3_–4dB
HD2_+20dB
HD2_+10dB
HD2_0dB
HD2_–M4dB
0
6725-016
Figure 17. Harmonic Distortion vs. Power at Four Gain Codes,
Frequency 140 MHz
70
–75
–80
–85
–90
–95
–100
–105
–110
HARMONIC DISTORTION HD2 AND HD3 (dBc)
40 60 80 100 120 140 160 180 200
FREQUENCY (MHz)
HD2 +25°C
HD3 +25°C
HD2 –40°C
HD3 –40°C
HD2 +85°C
HD3 +85°C
0
6725-017
Figure 18. Harmonic Distortion vs. Frequency, Three Temperatures,
V
OUT
= 2 V p-p
–120
–85
–115
–110
–105
–100
–95
–90
80
–5 –4 –3 –2 –1 0 1 2 3 4 5
–110
–105
–100
–95
–90
–85
–80
–75
70
HARMONIC DISTORTION HD3 (dBc)
P
OUT
(dBm)
HARMONIC DISTORTION HD2 (dBc)
HD3 +2C
HD3 +8C
HD3 –4C
HD2 –4C
HD2 +2C
HD2 +8C
06725-018
Figure 19. Harmonic Distortion vs. Power, Frequency 140 MHz,
Three Temperatures
35
40
30
25
20
15
10
5
0
NOISE FIGURE (dB)
–4 –2 0 2 4 6 8 10 12 14 16 18 20
GAIN (dB)
46MHz
70MHz
140MHz
200MHz
0
6725-019
Figure 20. NF vs. Gain at 46 MHz, 70 MHz, 140 MHz, and 200 MHz
45
40
35
30
25
20
15
10
5
0
0 100 200 300 400 500 600 700 800 900 1000
FREQUENCY (MHz)
NOISE FIGURE (dB)
A
V
= 0dB
A
V
= –4dB
A
V
= +10dB
A
V
= +20dB
06725-020
Figure 21. NF vs. Frequency