Datasheet
Data Sheet AD8370
Rev. B | Page 5 of 28
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Rating
Supply Voltage, V
S
5.5 V
PWUP, DATA, CLCK, LTCH
V
S
+ 500 mV
Differential Input Voltage,
V
INHI
– V
INLO
2 V
Common-Mode Input Voltage,
V
INHI
or V
INLO,
with Respect to
ICOM or OCOM
V
S
+ 500 mV (max),
V
ICOM
– 500 mV,
V
OCOM
– 500 mV (min)
Internal Power Dissipation
575 mW
θ
JA
(Exposed Paddle Soldered Down) 30°C/W
θ
JA
(Exposed Paddle Not Soldered Down) 95°C/W
θ
JC
(At Exposed Paddle) 9°C/W
Maximum Junction Temperature 150°C
Operating Temperature Range −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Lead Temperature Range
(Soldering 60 sec)
235°C
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate
on the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic di
scharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.