Parameter Conditions Min Typ Max Unit
190 MHz
Second/Third Harmonic Distortion R
L
= 1 kΩ, V
OUT
= 2 V p-p −82/−85 dBc
R
L
= 200 Ω, V
OUT
= 2 V p-p −81/−87 dBc
Output Third-Order Intercept R
L
= 200 Ω, f
1
= 180.5 MHz, f
2
= 190.5 MHz 39 dBm
Third-Order IMD
R
L
= 1 kΩ, f
1
= 180.5 MHz, f
2
= 190.5 MHz,
V
OUT
= 2 V p-p composite
−83 dBc
R
L
= 200 Ω, f
1
= 180.5 MHz, f
2
= 190.5 MHz,
V
OUT
= 2 V p-p composite
−81 dBc
Noise Spectral Density (RTI) 2.7 nV/√Hz
1 dB Compression Point (RTO) 15.4 dBm
240 MHz
Second/Third Harmonic Distortion R
L
= 1 kΩ, V
OUT
= 2 V p-p −82/−76 dBc
R
L
= 200 Ω, V
OUT
= 2 V p-p −80/−73 dBc
Output Third-Order Intercept R
L
= 200 Ω, f
1
= 239.5 MHz, f
2
= 240.5 MHz 36 dBm
Third-Order IMD
R
L
= 1 kΩ, f
1
= 239.5 MHz, f
2
= 240.5 MHz,
V
OUT
= 2 V p-p composite
−85 dBc
R
L
= 200 Ω, f
1
= 239.5 MHz, f
2
= 240.5 MHz,
V
OUT
= 2 V p-p composite
−77 dBc
Noise Spectral Density (RTI) 2.7 nV/√Hz
1 dB Compression Point (RTO) 15.3 dBm
380 MHz
Second/Third Harmonic Distortion
2
R
L
= 1 kΩ, V
OUT
= 2 V p-p −72/−68 dBc
R
L
= 200 Ω, V
OUT
= 2 V p-p −74/−69 dBc
Output Third-Order Intercept R
L
= 200 Ω, f
1
= 379.5 MHz, f
2
= 380.5 MHz 33 dBm
Third-Order IMD
R
L
= 1 kΩ, f
1
= 379.5 MHz, f
2
= 380.5 MHz,
V
OUT
= 2 V p-p composite
−74 dBc
R
L
= 200 Ω, f
1
= 379.5 MHz, f
2
= 380.5 MHz,
V
OUT
= 2 V p-p composite
−70 dBc
Noise Spectral Density (RTI) 2.7 nV/√Hz
1 dB Compression Point (RTO) 14.6 dBm
500 MHz
Second/Third Harmonic Distortion
2
R
L
= 200 Ω, V
OUT
= 2 V p-p −71/−64 dBc
Output Third-Order Intercept R
L
= 200 Ω, f
1
= 499.5 MHz, f
2
= 500.5 MHz 28 dBm
Third-Order IMD
R
L
= 200 Ω, f
1
= 499.5 MHz, f
2
= 500.5 MHz,
V
OUT
= 2 V p-p composite
−61 dBc
Noise Spectral Density (RTI) 2.7 nV/√Hz
1 dB Compression Point (RTO) 13.9 dBm
1
When using the evaluation board at frequencies below 50 MHz, replace the Output Balun T1 with a transformer, such as Mini-Circuits® ADT1-1WT to obtain the low
frequency balance required for differential HD2 cancellation.
2
C
D
and R
D
can be optimized for broadband operation below 180 MHz. For operation above 300 MHz, C
D
and R
D
components are not required.