Datasheet

AD8210 Data Sheet
Rev. E | Page 4 of 15
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Rating
Supply Voltage 12.5 V
Continuous Input Voltage (V
CM
)
−5 V to +68 V
Reverse Supply Voltage 0.3 V
ESD Rating
HBM (Human Body Model) ±4000 V
CDM (Charged Device Model) ±1000 V
Operating Temperature Range −40°C to +125°C
Storage Temperature Range
−65°C to +150°C
Output Short-Circuit Duration Indefinite
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION