ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Rating
Supply Voltage 12 V
Continuous Input Voltage (Common Mode) −24 V to +80 V
Differential Input Voltage ±12 V
Reversed Supply Voltage Protection 0.3 V
ESD Human Body Model for Shunt-Based
Applications
1
±8000 V
Operating Temperature Range
AD8209WBRM
−40°C to +125°C
AD8209WHRM −40°C to +150°C
Storage Temperature Range −65°C to +150°C
Output Short-Circuit Duration Indefinite
Lead Temperature Range (Soldering 10 sec) 300°C
1
Shunt-based applications have a low impedance shunt resistor between +IN
and –IN. See Figure 24 for an example of a shunt-based application.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION