Datasheet

AD7992
Rev. 0 | Page 8 of 28
PIN CONFIGURATION AND PIN FUNCTION DESCRIPTIONS
AD7992
TOP VIEW
1
2
3
4
7
8
9
10
SDA
SCL
V
DD
AGND
AGND
5
(Not to Scale)
ALERT
6
AS
V
IN
1
V
IN
2/REF
IN
03263-0-002
CONVST
Figure 3. AD7992 Pin Configuration
Table 5. Pin Function Descriptions
Pin No. Mnemonic Function
2, 7 AGND
Analog Ground. Ground reference point for all circuitry on the AD7992. All analog input signals should be
referred to this GND voltage.
3 V
DD
Power Supply Input. The V
DD
range for the AD7992 is from 2.7 V to 5.5 V.
4 V
IN
2/REF
IN
Analog Input 2/Voltage Reference Input. In single-channel mode, this pin becomes the reference voltage input;
an external reference should be applied at this pin. The external reference input range is 1.2 V to V
DD
. A 0.1 µF
and 1µF capacitor should be tied between this pin and AGND. If Bit D6 is set to 1 in the configuration register,
the AD7992 operates in single-channel mode. In dual-channel mode, D6 in the configuration register is 0; in
this case, this pin provides the second analog input channel. The reference voltage for the AD7992 is taken
from the power supply voltage in dual-channel mode. See the Configuration Register section and Table 10.
5 V
IN
1 Analog Input 1. Single-ended analog input channel. The input range is 0 V to REF
IN
.
6 AS Logic Input. Address select input that selects one of three I
2
C addresses for the AD7992, as shown in Table 6.
1
CONVST Logic Input Signal. Convert start signal. This is an edge-triggered logic input. The rising edge of this signal
powers up the part. The power up time for the part is 1 µs. The falling edge of
CONVST places the track-and-
hold into hold mode and initiates a conversion. A power-up time of at least 1 µs must be allowed for the
CONVST high pulse; otherwise, the conversion result is invalid (see the Modes of Operation section).
8 ALERT/BUSY
Digital Output. Selectable as an ALERT or BUSY output function. When configured as an ALERT, this pin acts as
an out-of-range indicator and, if enabled, becomes active when the conversion result violates the DATA
HIGH
or
DATA
LOW
register values. See the Limit Registers section. When configured as a BUSY output, this pin becomes
active when a conversion is in progress. Open-drain output. An external pull-up resistor is required.
9 SDA Digital I/O. Serial bus bidirectional data. Open-drain output. An external pull-up resistor is required.
10 SCL Digital Input. Serial bus clock. Open-drain output. An external pull-up resistor is required.
Table 6. I
2
C Address Selection
Part Number AS Pin I
2
C Address
AD7992-0 GND 010 0001
AD7992-0 V
DD
010 0010
AD7992-1 GND 010 0011
AD7992-1 V
DD
010 0100
AD7992-x
1
Float 010 0000
1
If the AS pin is left floating on any of the AD7992 parts, the device address is 010 0000. This gives each AD7992 device three different address options.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.