Datasheet

AD795
Rev. C | Page 4 of 20
AD795JR
Parameter Test Conditions/Comments Min Typ Max Unit
POWER SUPPLY
Rated Performance ±15 V
Operating Range ±4 ±18 V
Quiescent Current 1.3 1.5 mA
1
Input offset voltage specifications are guaranteed after 5 minutes of operation at T
A
= +25°C.
2
Bias current specifications are guaranteed maximum at either input after 5 minutes of operation at T
A
= +25°C. For higher temperature, the current doubles every 10°C.
3
Gain = −1, R1 = 10 kΩ.
4
Defined as the time required for the amplifier’s output to return to normal operation after removal of a 50% overload from the amplifier input.
5
Defined as the maximum continuous voltage between the inputs such that neither input exceeds ±10 V from ground.