Datasheet

Data Sheet AD7949
Rev. E | Page 15 of 32
TRANSFER FUNCTIONS
With the inputs configured for unipolar range (single-ended,
COM with ground sense, or paired differentially with INx− as
ground sense), the data output is straight binary.
With the inputs configured for bipolar range (COM = V
REF
/2 or
paired differentially with INx− = V
REF
/2), the data outputs are
twos complement.
The ideal transfer characteristic for the AD7949 is shown in
Figure 24 and for both unipolar and bipolar ranges with the
internal 4.096 V reference.
100...000
100...001
100...010
011...101
011...110
011...111
TWOS
COMPLEMENT
STRAIGHT
BINARY
000...000
000...001
000...010
111...101
111...110
111...111
ADC CODE
ANALOG INPUT
+FSR – 1.5LSB
+FSR – 1LSB
–FSR + 1LSB
–FSR
–FSR + 0.5LSB
07351-024
Figure 24. ADC Ideal Transfer Function
Table 7. Output Codes and Ideal Input Voltages
Description
Unipolar Analog Input
1
V
REF
= 4.096 V
Digital Output Code
(Straight Binary Hex)
Bipolar Analog Input
2
V
REF
= 4.096 V
Digital Output Code
(Twos Complement Hex)
FSR − 1 LSB 4.095750 V 0x3FFF
3
2.047750 V 0x1FFF
3
Midscale + 1 LSB 2.048250 V 0x2001 250 μV 0x0001
Midscale 2.048000 V 0x2000 0 V 0x0000
Midscale − 1 LSB 2.047750 V 0x1FFF −250 μV 0x3FFF
−FSR + 1 LSB 250 μV 0x0001 −2.047750 V 0x2001
−FSR 0 V 0x0000
4
−2.048 V 0x2000
4
1
With COM or INx− = 0 V or all INx referenced to GND.
2
With COM or INx− = V
REF
/2.
3
This is also the code for an overranged analog input ((INx+) − (INx−), or COM, above V
REF
− GND).
4
This is also the code for an underranged analog input ((INx+) − (INx−), or COM, below GND).
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.