SCLK
DOUT
DIN
CS
1 1614 1 1614
PART IS IN
UNKNOWN MODE
AFTER POWER-ON
ALLOW
t
POWER
TO ELAPSE
IF IN SHUTDOWN AT POWER-ON,
PART BEGINS TO POWER UP ON
CS RISING EDGE AS PM1 = PM0 = 1
t
12
DIN LINE HIGH FOR FIRST DUMMY CONVERSION TO KEEP THE PART IN NORMAL MODE, LOAD
PM1 = PM0 = 1 IN CONTROL REGISTER
INVALID DATA CHANNEL IDENTIFIER BITS + CONVERSION RESULT
DATA IN TO CONTROL REGISTER
03087-023
Figure 23. Placing the AD7904/AD7914/AD7924 into Normal Mode After Supplies Are First Applied
SCLK
DOUT
DIN
CS
PART IS IN
UNKNOWN MODE
AFTER POWER-ON
PART ENTERS SHUTDOWN ON
CS RISING EDGE AS PM1 = 1, PM0 = 0
1 14 16
INVALID DATA
DATA IN TO CONTROL REGISTER
CONTROL REGISTER IS LOADED ON
THE FIRST 12 CLOCKS. PM1 = 1, PM0 = 0
03087-024
Figure 24. Placing the AD7904/AD7914/AD7924 into Full Shutdown Mode After Supplies Are First Applied
SCLK
DOUT
DIN
CS
PART ENTERS AUTO SHUTDOWN ON
CS RISING EDGE AS PM1 = 0, PM0 = 1
1 14 16 1 14 16
PART IS IN
UNKNOWN MODE
AFTER POWER-ON
INVALID DATA
INVALID DATA
DATA IN TO CONTROL REGISTER
DIN LINE HIGH FOR FIRST DUMMY CONVERSION CONTROL REGISTER IS LOADED ON THE
FIRST 12 CLOCKS. PM1 = 0, PM0 = 1
03087-025
Figure 25. Placing the AD7904/AD7914/AD7924 into Auto Shutdown Mode After Supplies Are First Applied