Datasheet
AD7846
Rev. G | Page 6 of 24
ABSOLUTE MAXIMUM RATINGS
Table 4.
Parameter Rating
V
DD
to DGND −0.4 V to +17 V
V
CC
to DGND −0.4 V, V
DD
+ 0.4 V, or +7 V
(whichever is lower)
V
SS
to DGND +0.4 V to −17 V
V
REF+
to DGND V
DD
+ 0.4 V, V
SS
− 0.4 V
V
REF−
to DGND V
DD
+ 0.4 V, V
SS
− 0.4 V
V
OUT
to DGND
1
V
DD
+ 0.4 V, V
SS
− 0.4 V, or ±10 V
(whichever is lower)
R
IN
to DGND V
DD
+ 0.4 V, V
SS
− 0.4 V
Digital Input Voltage to DGND −0.4 V to V
CC
+ 0.4 V
Digital Output Voltage to DGND −0.4 V to V
CC
+ 0.4 V
Power Dissipation (Any Package)
To +75°C 1000 mW
Derates above +75°C 10 mW/°C
Operating Temperature Range
J, K Versions 0°C to +70°C
A, B Versions −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Lead Temperature (Soldering) +300°C
1
V
OUT
can be shorted to DGND, V
DD
, V
SS
, or V
CC
provided that the power
dissipation of the package is not exceeded.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION