–5–
ABSOLUTE MAXIMUM RATINGS*
(T
A
= 25C, unless otherwise noted.)
V
DD
to GND . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 V to +7 V
Analog Input Voltage to GND . . . . . . . 0.3 V to V
DD
+ 0.3 V
Reference Input Voltage to GND . . . . 0.3 V to V
DD
+ 0.3 V
Total AIN/REFIN Current (Indefinite) . . . . . . . . . . . . . 30 mA
Digital Input Voltage to GND . . . . . . . 0.3 V to V
DD
+ 0.3 V
Digital Output Voltage to GND . . . . . 0.3 V to V
DD
+ 0.3 V
Operating Temperature Range . . . . . . . . . . . 40C to +85C
Storage Temperature Range . . . . . . . . . . . . 65C to +150C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 150C
TSSOP Package
JA
Thermal Impedance . . . . . . . . . . . . . . . . . . . . 97.9C/W
JC
Thermal Impedance . . . . . . . . . . . . . . . . . . . . . . 14C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . . 215C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220C
*Stresses above those listed under Absolute Maximum Ratings may cause per-
manent damage to the device. This is a stress rating only; functional operation of
the device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
CS (I)
DOUT/RDY (O)
SLAVE MODE
SCLK (I)
MASTER MODE
SCLK (O)
I = INPUT TO AD7783, AND O = OUTPUT FROM AD7783.
SLAVE MODE IS SELECTED BY TYING THE MODE PIN
+,*+, WHILE MASTER MODE IS SELECTED BY TYING THE MODE PIN /2:.
t
2
t
3
t
4
t
5
t
6
t
4
t
10
t
5
t
6
t
8
t
7
t
9
MSB
MSB
LSB LSB
Figure 2. Slave/Master Mode Timing Diagram
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD7783 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
REV. C