Datasheet
AD7694
Rev. A | Page 6 of 16
ABSOLUTE MAXIMUM RATINGS
Table 6.
Parameter Rating
Analog Inputs
IN+
1
, IN−
1
GND − 0.3 V to VDD + 0.3 V
or ±130 mA
REF GND − 0.3 V to VDD + 0.3 V
Supply Voltages
VDD to GND −0.3 V to +7 V
Digital Inputs to GND −0.3 V to VDD + 0.3 V
Digital Outputs to GND −0.3 V to VDD + 0.3 V
Storage Temperature Range −65°C to +150°C
Junction Temperature 150°C
θ
JA
Thermal Impedance 200°C/W (MSOP-8)
θ
JC
Thermal Impedance 44°C/W (MSOP-8)
Lead Temperature Range
Vapor Phase (60 sec) 215°C
Infrared (15 sec) 220°C
1
See the Analog Input section.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
05003-002
500μAI
OL
500μAI
OH
1.4VTO SDO
C
L
50pF
Figure 2. Load Circuit for Digital Interface Timing
V
IL
V
IH
V
OH
V
OL
V
OL
V
OH
t
DELAY
t
DELAY
05003-003
Figure 3. Voltage Reference Levels for Timing