Datasheet

AD7655
Rev. B | Page 19 of 28
Slave Parallel Interface
In slave parallel reading mode, the data can be read either after
each conversion, which is during the next acquisition phase, or
during the other channel’s conversion, or during the following
conversion, as shown in
Figure 24 and Figure 25, respectively.
When the data is read during the conversion, however, it is
recommended that it is read only during the first half of the
conversion phase. This avoids any potential feedthrough
between voltage transients on the digital interface and the most
critical analog conversion circuitry.
DATA BUS
t
18
t
19
BUSY
CURRENT
CONVERSION
CS
RD
03536-024
Figure 24. Slave Parallel Data Timing for Reading (Read after Convert)
PREVIOUS
CONVERSION
t
1
t
3
t
18
t
19
t
4
BUSY
DATA BUS
t
13
t
11
t
12
t
10
CS = 0
EOC
CNVST, RD
03536-025
Figure 25. Slave Parallel Data Timing for Reading (Read During Convert)
8-Bit Interface (Master or Slave)
The BYTESWAP pin allows a glueless interface to an 8-bit bus.
As shown in
Figure 26, the LSB byte is output on D[7:0] and the
MSB is output on D[15:8] when BYTESWAP is low. When
BYTESWAP is high, the LSB and MSB bytes are swapped, the
LSB is output on D[15:8], and the MSB is output on D[7:0]. By
connecting BYTESWAP to an address line, the 16-bit data can
be read in 2 bytes on either D[15:8] or D[7:0].
BYTESWAP
PINS D[15:8]
PINS D[7:0]
HI-Z
HI-Z
HIGH BYTE LOW BYTE
LOW BYTE HIGH BYTE
HI-Z
HI-Z
t
18
t
18
t
19
CS
RD
03536-026
Figure 26. 8-Bit Parallel Interface
Channel A/
B
Output
The A/
B
input controls which channel’s conversion results
(INAx or INBx) are output on the data bus. The function-ality
of A/
B
is detailed in Figure 27. When high, the data from
Channel A is available on the data bus. When low, the data from
Channel B is available on the bus. Note that in parallel reading
mode, Channel A can be read immediately after the end of
conversion (
EOC
), while Channel B is still in its converting
phase. However, in any of the serial reading modes Channel A
data is updated only after Channel B conversion.
t
18
t
20
CS
DATA BU
S
RD
HI-Z
A/B
HI-Z
CHANNEL A
CHANNEL B
03536-027
Figure 27. A/
B
Channel Reading