Datasheet
AD7651
MASTER SERIAL INTERFACE
Usually, because the AD7651 has a longer acquisition phase than
the conversion phase, the data is read immediately after conversion.
This makes the Master Read After Conversion the most recom-
mended serial mode when it can be used. In this mode, it should be
noted that unlike in other modes, the BUSY signal returns LOW
after the 16 data bits are pulsed out and not at the end of the
conversion phase, which results in a longer BUSY width.
Internal Clock
The AD7651 is configured to generate and provide the serial data
clock SCLK when the EXT/
INT
pin is held LOW. The AD7651 also
generates a SYNC signal to indicate to the host when the serial data
is valid. The serial clock SCLK and the SYNC signal can be inverted
if desired. Depending on the RDC/SDIN input, the data can be read
after each conversion or during the following conversion. Figure 32
and Figure 33 show detailed timing diagrams of these two modes.
In the Read During Conversion mode, the serial clock and data
toggle at appropriate instants, which minimize potential feed-
through between digital activity and critical conversion decisions
t
3
BUSY
SYNC
SCLK
SDOUT
t
28
t
29
t
14
t
18
t
19
t
20
t
21
t
24
t
26
t
27
t
23
t
22
t
16
t
15
123 141516
D15 D14 D2 D1 D0
X
RDC/SDIN = 0 INVSCLK = INVSYNC = 0
t
25
t
30
02964-0-015
CNVST
CS, RD
EXT/INT = 0
Figure 32. Master Serial Data Timing for Reading (Read after Convert)
EXT/INT = 0 RDC/SDIN = 1 INVSCLK = INVSYNC = 0
t
3
t
1
t
17
t
14
t
19
t
20
t
21
t
24
t
26
t
25
t
27
t
23
t
22
t
16
t
15
D15 D14 D2 D1 D0X
12 3 141516
t
18
BUSY
SYNC
SCLK
SDOUT
02964-0-016
CNVST
CS, RD
Figure 33. Master Serial Data Timing for Reading (Read Previous Conversion during Convert)
Rev. 0 | Page 21 of 28