Parameter Test Conditions/Comments Min Typ Max Unit
Power Dissipation
Normal Mode (Static) AD7606 80 115.5 mW
Normal Mode (Operational)
8
f
SAMPLE
= 200 kSPS
AD7606 100 142 mW
AD7606-6
126
mW
AD7606-4 75 111 mW
Standby Mode 25 42 mW
Shutdown Mode 10 31.5 µW
1
Temperature range for the B version is −40°C to +85°C. The AD7606 is operational up to 125°C with throughput rates ≤ 160 kSPS, and the SNR typically reduces by
0.7 dB at 125°C.
2
See the Terminology section.
3
This specification applies when reading during a conversion or after a conversion. If reading during a conversion in parallel mode with V
DRIVE
= 5 V, SNR typically reduces by 1.5 dB
and THD by 3 dB.
4
LSB means least significant bit. With ±5 V input range, 1 LSB = 152.58 µV. With ±10 V input range, 1 LSB = 305.175 µV.
5
These specifications include the full temperature range variation and contribution from the internal reference buffer but do not include the error contribution from
the external reference.
6
Bipolar zero code error is calculated with respect to the analog input voltage. See the Analog Input Clamp Protection section.
7
Sample tested during initial release to ensure compliance.