Datasheet

AD7482
Rev. B | Page 5 of 20
TIMING CHARACTERISTICS
AV
DD
/DV
DD
= 5 V ± 5%, AGND = DGND = 0 V, V
REF
= external; all specifications T
MIN
to T
MAX
and valid for V
DRIVE
= 2.7 V to 5.25 V,
unless otherwise noted.
Table 2.
Parameter
1
Symbol Min Typ Max Unit
DATA READ
Conversion Time t
CONV
300 ns
Quiet Time Before Conversion Start t
QUIET
100 ns
CONVST
t
1
Pulse width 5 100
ns
CONVST
Falling Edge to
t
2
BUSY
Falling Edge 20
ns
CS
Falling Edge to
t
3
RD
Falling Edge 0
ns
Data Access Time t
4
25 ns
CONVST
t
5
Falling Edge to New Data Valid 30
ns
BUSY
t
6
Rising Edge to New Data Valid 5
ns
Bus Relinquish Time t
7
10 ns
RD
Rising Edge to
t
8
CS
Rising Edge 0
ns
CS
t
14
Pulse width 30
ns
RD
t
15
Pulse width 30
ns
DATA WRITE
WRITE Pulse Width t
9
5 ns
Data Setup Time t
10
2 ns
Data Hold Time t
11
6 ns
CS
t
12
Falling Edge to WRITE Falling Edge 5
ns
WRITE Falling Edge to
CS
t
13
Rising Edge 0
ns
1