Datasheet

Data Sheet AD737
Rev. I | Page 5 of 24
Parameter
Test Conditions/
Comments
AD737A, AD737J AD737K AD737J-5
Unit Min Typ Max Min Typ Max Min Typ Max
3 dB Bandwidth V
IN
= 1 mV rms 5 5 5 kHz
V
IN
= 10 mV rms 55 55 55 kHz
V
IN
= 100 mV rms 170 170 170 kHz
V
IN
= 200 mV rms 190 190 190 kHz
Low-Z Input
(Pin 1)
1% Additional
Error
V
IN
= 1 mV rms 1 1 1 kHz
V
IN
= 10 mV rms 6 6 6 kHz
V
IN
= 40 mV rms 25 kHz
V
IN
= 100 mV rms 90 90 90 kHz
V
IN
= 200 mV rms 90 90 90 kHz
3 dB Bandwidth V
IN
= 1 mV rms 5 5 5 kHz
V
IN
= 10 mV rms 55 55 55 kHz
IN
350
350
350
kHz
V
IN
= 200 mV rms 460 460 460 kHz
POWER-DOWN
MODE
Disable Voltage 0 0 V
Input Current,
PD Enabled
V
PD
= V
S
11 11 µA
POWER SUPPLY
Operating
Voltage Range
+2.8/
−3.2
±5 ±16.5
+2.8/
−3.2
±5 ±16.5 ±2.5 ±5 ±16.5 V
Current No input 120
160
120
160
120
160
µA
Rated input 170 210 170 210 170 210 µA
Powered down 25 40 25 40 25 40 µA
1
POR is % of reading.
2
Nonlinearity is defined as the maximum deviation (in percent error) from a straight line connecting the readings at 0 V and at 200 mV rms.
3
After fourth-order error correction using the equation
y = 0.31009x
4
0.21692x
3
0.06939x
2
+ 0.99756x + 11.1 × 10
−6
where y is the corrected result and x is the device output between 0.01 V and 0.3 V.
4
Crest factor error is specified as the additional error resulting from the specific crest factor, using a 200 mV rms signal as a reference. The crest factor is defined as
V
PEAK
/V rms.
5
DC offset does not limit ac resolution.
6
Value is measured with respect to COM.