SHUTDOWN MODE
Shutdown mode is intended for use in applications where slow
throughput rates are required. Shutdown mode is suited to
applications where a series of conversions performed at a
relatively high throughput rate are followed by a long period
of inactivity and thus, shutdown. When the AD7366/AD7367
are in full power-down, all analog circuitry is powered down.
The falling edge of
CNVST
initiates the conversion. The BUSY
output subsequently goes high to indicate that the conversion is
in progress. After the conversion is completed, the BUSY output
returns low. If the
CNVST
signal is at logic low when BUSY
goes low, the part enters shutdown at the end of the conversion
phase. While the part is in shutdown mode, the digital output
code from the last conversion on each ADC can still be read
from the D
OUT
pins. To read the D
OUT
data,
CS
must be brought
low as described in the
Serial Interface section. The D
OUT
pins
return to three-state when
CS
is brought back to logic high.
To exit full power-down and to power up the AD7366/AD7367,
a rising edge of
CNVST
is required. After the required power-up
time has elapsed,
CNVST
can be brought low again to initiate
another conversion, as shown in
Figure 24 (see the Power-Up
Times section for power-up times associated with the AD7366/
AD7367).
POWER-UP TIMES
The AD7366/AD7367 have one power-down mode, which is
described in detail in the Shutdown Mode
section. This section
deals with the power-up time required when coming out of
shutdown mode. It should be noted that the power-up times (as
explained in this section) apply with the recommended capaci-
tors in place on the D
CAP
A and D
CAP
B pins. To power up from
shutdown,
CNVST
must be brought high and remain high for a
minimum of 70 μs, as shown in
Figure 24.
When power supplies are first applied to the AD7366/AD7367,
the ADC can power up with
CNVST
in either the low or high
logic state. Before attempting a valid conversion,
CNVST
must
be brought high and remain high for the recommended power-
up time of 70 μs. Then
CNVST
can be brought low to initiate a
conversion. With the AD7366/AD7367, no dummy conversion
is required before valid data can be read from the
D
OUT
pins.
To place the part in shutdown mode when the supplies are first
applied, the AD7366/AD7367 must be powered up and a
conversion initiated. However,
CNVST
should remain in the
logic low state so that when the BUSY signal goes low, the part
enters shutdown.
When supplies are applied to the AD7366/AD7367, sufficient
time must be allowed for any external reference to power up and
to charge the various reference buffer decoupling capacitors to
their final values.
BUSY
SCLK
SERIAL READ OPERATION
CS
1
12
t
CONVERT
t
3
t
2
ENTERS SHUTDOWN
t
POWER-UP
06703-026
CNVST
Figure 24. Autoshutdown Mode for the AD7366