Table XIII. Control Register G Description
76543210
SEEN RMOD CH6 CH5 CH4 CH3 CH2 CH1
Bit Name Description
0 CH1 Channel 1 Select
1 CH2 Channel 2 Select
2 CH3 Channel 3 Select
3 CH4 Channel 4 Select
4 CH5 Channel 5 Select
5 CH6 Channel 6 Select
6 RMOD Reset Analog Modulator
7 SEEN Enable Single-Ended Input Mode
Table XIV. Control Register H Description
76543210
INV TME CH6 CH5 CH4 CH3 CH2 CH1
Bit Name Description
0 CH1 Channel 1 Select
1 CH2 Channel 2 Select
2 CH3 Channel 3 Select
3 CH4 Channel 4 Select
4 CH5 Channel 5 Select
5 CH6 Channel 6 Select
6 TME Test Mode Enable
7 INV Enable Invert Channel Mode
CONTROL REGISTER G
CONTROL REGISTER H
REGISTER BIT DESCRIPTIONS
Control Register A
CRA:0 Data/Program Mode. This bit controls the operating mode of the AD73360. If CRA:1 is 0, then a 0 in this bit
places the part in Program Mode. If CRA:1 is 0, then a 1 in this bit places the part in Data Mode.
CRA:1 Mixed Mode. If this bit is a 0, then the operating mode is determined by CRA:0. If this bit is a 1, then the
part operates in Mixed Mode.
CRA:2 Reserved. This bit is reserved and should be programmed to 0 to ensure correct operation.
CRA:3 SPORT Loop Back. This is a diagnostic mode. This bit should be set to 0 to ensure correct operation.
CRA:46 Device Count Bits. These bits tell the AD73360 how many devices are used in a cascade. All devices in the
cascade should be programmed to the same value ensure correct operation. See Table XVIII.
CRA:7 Reset. Writing a 1 to this bit will initiate a software reset of the AD73360.
Control Register B
CRB:01 Decimation Rate. These bits are used to set the decimation of the AD73360. See Table VII.
CRB:23 Serial Clock Divider. These bits are used to set the serial clock frequency. See Table VI.
CRB:46 Master Clock Divider. These bits are used to set the Master Clock Divider ratio. See Table V.
CRB:7 Control Echo Enable. Setting this bit to a 1 will cause the AD73360 to write out any control words it receives.
This is used as a diagnostic mode. This bit should be set to 0 for correct operation in Mixed Mode or Data Mode.