Datasheet

AD7323 Data Sheet
Rev. B | Page 6 of 36
B Version
Parameter
1
Min Typ Max Unit Test Conditions/Comments
Autoshutdown Mode (Static) SCLK on or off
I
DD
1 µA V
DD
= 16.5 V
I
SS
1 µA V
SS
= −16.5 V
I
CC
and I
DRIVE
1 µA V
CC
/V
DRIVE
= 5.25 V
Full Shutdown Mode SCLK on or off
I
DD
1 µA V
DD
= 16.5 V
I
SS
1 µA V
SS
= −16.5 V
I
CC
and I
DRIVE
1 µA V
CC
/V
DRIVE
= 5.25 V
POWER DISSIPATION
Normal Mode (Operational) 18 mW V
DD
= 16.5 V, V
SS
= −16.5 V, V
CC
= 5.25 V
Full Shutdown Mode 38.25 µW V
DD
= 16.5 V, V
SS
= −16.5 V, V
CC
= 5.25 V
1
Temperature range is −40°C to +85°C.
2
See the Terminology section.
3
Sample tested during initial release to ensure compliance.
4
Unipolar 0 V to 10 V range with straight binary output coding.
5