SERIAL INTERFACE
Figure 51 shows the timing diagram for the serial interface of
the AD7323. The serial clock applied to the SCLK pin provides
the conversion clock and controls the transfer of information to
and from the AD7323 during a conversion.
The
CS
signal initiates the data transfer and the conversion
process. The falling edge of
CS
puts the track-and-hold into
hold mode and takes the bus out of three-state. Then the analog
input signal is sampled. When the conversion is initiated, it
requires 16 SCLK cycles to complete.
The track-and-hold goes back into track mode on the 14
th
SCLK
rising edge. On the 16
th
SCLK falling edge, the DOUT line returns
to three-state. If the rising edge of
CS
occurs before 16 SCLK
cycles have elapsed, the conversion is terminated, and the
DOUT line returns to three-state. Depending on where the
CS
signal is brought high, the addressed register may be updated.
Data is clocked into the AD7323 on the SCLK falling edge. The
three MSBs on the DIN line are decoded to select which register
is being addressed. The control register is a 12-bit register. If the
control register is addressed by the three MSBs, the data on the
DIN line is loaded into the control on the 15
th
SCLK falling
edge. If the sequence register or the range register is addressed,
the data on the DIN line is loaded into the addressed register on
the 11
th
SCLK falling edge.
Conversion data is clocked out of the AD7323 on each SCLK
falling edge. Data on the DOUT line consists of a zero bit, two
channel identifier bits, a sign bit, and a 12-bit conversion result.
The channel identifier bits are used to indicate which channel
corresponds to the conversion result. The zero bit is clocked out
on the
CS
falling edge, and the ADD1 bit is clocked out on the
first SCLK falling edge.
ADD1
1 2 3 4 5 13 14 15 16
WRITE
REG
SEL1
REG
SEL2
LSBMSB
ADD0 SIGN DB11 DB10 DB2 DB1 DB0
t
2
t
6
t
4
t
9
t
10
t
3
t
7
t
5
t
8
t
1
t
QUIET
t
CONVERT
SCLK
CS
DOUT
THREE-
STATE
THREE-STATE
DIN
ZERO
2 IDENTIFICATION BITS
05400-036
DON’T
CARE
Figure 51. Serial Interface Timing Diagram (Control Register Write)