MODES OF OPERATION
The AD7321 has several modes of operation that are designed
to provide flexible power management options. These options
are chosen to optimize the power dissipation/throughput rate
ratio for different application requirements. The mode of
operation of the AD7321 is controlled by the power management
bits, Bit PM1 and Bit PM0, in the control register as shown in
Table 11. The default mode is normal mode, where all internal
circuitry is fully powered up.
NORMAL MODE
(PM1 = PM0 = 0)
This mode is intended for the fastest throughput rate performance
with the AD7321 being fully powered up at all times. Figure 45
shows the general operation of the AD7321 in normal mode.
The conversion is initiated on the falling edge of
CS
, and the
track-and-hold section enters hold mode as described in the
Serial Interface section. Data on the DIN line during the
16 SCLK transfer is loaded into one of the on-chip registers if
the write bit is set. The register is selected by programming the
register select bits (see Table 8).
1 16
2 LEADING ZEROS, CHANNEL I.D. BIT, SIGN BIT
+ CONVERSION RESULT
DATA INTO CONTROL/RANGE REGISTER
SCLK
CS
DOUT
DIN
05399-035
Figure 45. Normal Mode
The AD7321 remains fully powered up at the end of the
conversion if both PM1 and PM0 contain 0 in the control
register.
To complete the conversion and access the conversion result,
16 serial clock cycles are required. At the end of the conversion,
CS
can idle either high or low until the next conversion.
Once the data transfer is complete, another conversion can be
initiated after the quiet time, t
QUIET
, has elapsed.
FULL SHUTDOWN MODE
(PM1 = PM0 = 1)
In this mode, all internal circuitry on the AD7321 is powered
down. The part retains information in the registers during full
shutdown. The AD7321 remains in full shutdown mode until
the power management bits, Bit PM1 and Bit PM0, in the
control register are changed.
A write to the control register with PM1 = 1 and PM0 = 1 places
the part into full shutdown mode. The AD7321 enters full shut-
down mode on the 15
th
SCLK rising edge once the control register
is updated.
If a write to the control register occurs while the part is in full
shutdown mode with the power management bits, Bit PM1 and
Bit PM0, set to 0 (normal mode), the part begins to power up
on the 15
th
SCLK rising edge once the control register is
updated. Figure 46 shows how the AD7321 is configured to exit
full shutdown mode. To ensure the AD7321 is fully powered up,
t
POWER-UP
should elapse before the next
CS
falling edge.
C
S
1 16 1 1
6
S
CLK
SDA
TA
DIN
INVALID D
ATA CHANN
EL IDENT
IFIER
BITS + CO
NVERSION RESUL
T
D
ATA INTO CON
TROL R
EGISTER D
ATA I
NTO CONT
ROL REGISTER
t
POWER-UP
THE PART IS FULLY PO
WE
RE
D U
P
ONC
E
t
POWER-UP
HAS ELAPSED
C
ONTROL REGIST
ER IS LOAD
ED ON THE FIR
ST 15 CL
OCKS,
PM
1 = 0, PM0
= 0
TO KEEP T
HE PART IN NOR
MAL MODE
, LOAD PM1 = PM0
= 0
IN CONTROL
REGISTER
PART I
S IN
FUL
L
SHU
TDO
WN
PART BEGINS TO POWE
R U
P
ON
THE 15
TH
SCLK
RISING EDGE AS PM1 = PM0
= 0
05399-041
Figure 46. Exiting Full Shutdown Mode